Use and Care Manual
- 5 -
MODEL NO
CELLAR
SIZE
(cu ft)
AIR
FLOW
(cfm)
AIR FILTER
(“, nominal)
DUCT
(“)
DIMENSIONS (“)
WxW1xD
xD1xD2xH
ELECTRICAL
RATING
WEIGHT
(lb)
WM-4510HZD 1000 300 11.5x13.5x1 8
14.375x0.25x21.5
x1.25x1x20
115V/60Hz/8A 95
WM-6510HZD 1500 500 13.5x14.5x1 10
17.125x0.25x28.375
x1.25x1x22.125
115V/60Hz/14A 140
WM-8510HZD 2000 500 13.5x14.5x1 10
17.125x0.25x28.375
x1.25x1x22.125
115V/60Hz/16A 140
NOTES:
• See the voltage, frequency and current specified on the label at the
cooling unit.
• The rated capacity is determined under the cellar and ambient
temperatures of 55°F and 75°F with R13 interior and R19 exterior
insulations. Any lower cellar temperature, higher ambient temperature
and less insulation will cause reducing capacity and may not maintain
55°F.
• The ambient temperatures shall not be higher than 100°F or lower than
50°F in order to operate properly.
Fig. 1.2 Dimensions