SDS
SECTION V - FIRE FIGHTING INFORMATION
Flash Point: None
NOT DETERMINED
Autoignition:
LEL: 1.2 %
UEL: 23.5 %
EXTINGUISHING MEDIA: ALCOHOL FOAM, CO2, DRY CHEMICAL, FOAM OR WATER FOG
FIRE/EXPLOSION HAZARDS: MATERIAL IS HIGHLY VOLATILE AND READILY GIVES OFF VAPORS WHICH MAY TRAVEL ALONG THE
GROUND AND IGNITED BY PILOT LIGHTS, FLAMES, SPARKS, HEATERS, SMOKING, ELECTRIC MOTORS, STATIC DISCHARGES OR
OTHER IGNITION SOURCE DISTANT FROM THE HANDLING POINT.
BURNING CAN PRODUCE CARBON MONOXIDE AND/OR CARBON DIOXIDE
FIRE FIGHTING: WATER MAY BE USED COOL CLOSED CONTAINERS TO PREVENT PRESSURE BUILD UP AND POSSIBLE AUTOIGNITION
OR EXPLOSION WHEN EXPOSED TO EXTREME HEAT
FIRE EQUIPMENT: WEAR A FULL FACE POSITIVE PRESSURE SELF CONTAINED BREATHING APPARATUS (SCBA) WHEN FIGHTING FIRE
SECTION VI - SPILL OR LEAK PRCEDURES
GENERAL SPILL PROCEDURE: ISOLATE SPILL OR LEAK AREA IMMEDIATELY. KEEP UNAUTHORIZED PERSONNEL AWAY. VENTILATE
AREA AND ELIMINATE ALL IGNITION SOURCES.
SMALL SPILLS: CLEAN UP WITH INERT MATERIALS AND DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL
REGULATIONS.
LARGE SPILLS: DIKE AHEAD OF SPILL FOR LATER DISPOSAL. DO NOT DISCHARGE EFFLUENT OF THIS PRODUCT INTO LAKES,
STREAMS OR OTHER WATERS UNLESS IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REQUIREMENTS.
VII - HANDLING AND STORAGE
KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE FROM HEAT, SPARKS AND OPEN FLAMES. CLOSED CONTAINERS MAY EXPLODE
WHEN EXPOSED TO EXTREME HEAT.
DO NOT STORE IN DIRECT SUNLIGHT, NEAR OPEN FLAMES/SPARKS OR AT TEMPERATURES EXCEEDING 120F
VIII - EXPOSURE CONTROLS
PROVIDE GENERAL AMD/OR LOCAL EXHAUST VENTILATION TO CONTROL AIRBORNE LEVELS BELOW THE EXPOSURE GUIDLINE
GENERAL VENTILATION MAY BE ADEQUATE FOR MAINTIANING AIRBORNE CONCENTRATIONS BELOW ESTABLISHED EXPOSURE LIMITS. IF
GENERAL VENTILATION IS INADEQUATE, SUPPLEMENTAL LOCAL EXHAUST MAY BE REQUIRED. WHERE EXPLOSIVE MIXTURE MAY BE
PRESENT, SYSTEMS SAFE FOR SUCH LOCATIONS SHOULD BE USED.
RECOMMENDED FOR PROLONGED OR REPEATED CONTACT. WEAR PROTECTIVE EQUIPMENT RECOMMENDED FOR USE WITH
CHEMICALS LISTED IN SECTION II
CONTAMINATED EQUIPMENT/GEAR: LAUNDER ALL CONTAMINATED CLOTHING PRIOR TO RE-USE
SECTION IX - PHYSICAL AND CHEMICAL PROPERTIES
Appearance
NOT DETERMINED
Odor
NOT DETERMINED
Physical State
NOT DETERMINED
Vapor Density
NOT DETERMINED
Evaporation Rate
IS SLOWER THAN ETHER
Boiling Range
NOT DETERMINED
SECTION X - STABILITY AND REACTIVITY
STABLE UNDER NORMAL CONDITIONS. KEEP AWAY FROM HEAT, SPARKS OR OPEN FLAMES.
AVOID CONTACT WITH STRONG OXIDIZING AGENTS
AVOID CONTACT WITH STRONG ACIDS, HALOGENS, NON-FERROUS METALS, BORON, CHLORITES, CHROMIUM TRIOXIDE,
DIMETHYL SULFATE, ETHYLENE OXIDE, GOLD, MERCURY, NITROGEN TETROXIDE AND OLEUM.
Page 3 of 4
5/5/2011 11:14:48AM
06500011f