Recommended Operating Conditions
(Ta
=
−
40 to 85°C)
Characteristic Symbol Test Condition Min Typ. Max Unit
Output sustaining voltage V
CE (SUS)
⎯ 0 ⎯ 50 V
Duty = 10% 0 ⎯ 350
APG
Duty = 50% 0 ⎯ 100
Duty = 10% 0 ⎯ 300
Output current
AFWG
I
OUT
t
pw
= 25 ms
7 Circuits
Ta = 85°C
T
j
= 120°C
Duty = 50% 0 ⎯ 90
mA/ch
Input voltage V
IN
⎯ 0 ⎯ 24 V
ULN2003A 2.8 ⎯ 24
Input voltage
(output on)
ULN2004A
V
IN
(ON)
I
OUT
= 400 mA
h
FE
= 800
6.2 ⎯ 24
V
ULN2003A ⎯ 0 ⎯ 0.7
Input voltage
(output off)
ULN2004A
V
IN
(OFF)
⎯ 0 ⎯ 1.0
V
Clamp diode reverse voltage V
R
⎯ ⎯ ⎯ 50 V
Clamp diode forward current I
F
⎯ ⎯ ⎯ 350 mA
APG Ta = 85°C ⎯ ⎯ 0.76
Power dissipation
AFWG
P
D
Ta = 85°C (Note) ⎯ ⎯ 0.65
W