User manual

Operating instructions
Pressure controller M-6
Technical specifications
IP 42
230V=2,7KW / 400V=5,5KW
50/60 Hz / max. 20A
Operating temperature: -10/+50°C
Max. pressure: 6 bar
Safety regulations
The user must ensure that all instructions
described here are observed.
The customer is responsible for the safety of the
devices and equipment used together with the
pressure controller.
The customer bears the risk and the
responsibility for all actions taken on the
switch for what ever reason.
Before switching on, it must be ensured
that the hood/cover is in the correct position.
The pressure controller must not be used in a
potentially explosive environment.
The pressure controller must not be exposed to
rain or a direct water jet.
Bild 1
Bild 1.1
Fig. l
The standard connection is ¼”, which can be
changed to ½ with the adapter provided.
The pressure pipe screw connection should be
made as gas-tight as possible.
The required switch-on and switch-off pressure
is achieved by turning the pressure adjustment
nut or the differential pressure adjustment
screw.
For this, the device must be installed ready for
operation and switched on by pulling the red
knob on the housing cover.
Fig. 1.1
The setting can only be changed in operation
and under pressure, by turning the pressure
adjustment nut in +/- direction. For switch-on
and switch-off pressure, see diagram.
Fig.2 Fig.2
Before making the electrical connection, the
locking screw on the housing cover must be
removed together with the hood.
The power supply connection is firmly screwed to
the upper terminals and the motor to the lower
terminals (pump or compressor).
The protective conductor is attached to the metal studs
on the side.
Then push the protection against accidental contact
(VBG4) over the insulator.
Mount the hood in the correct position and fix with
the fixing screw on the housing cover.
Attention: Before connection,
disconnect unit from power
supply!!! Remove plug or set
fuse to off.
General
The drawings shown are only intended as a guide and are
not necessary accurate in every detail.
The features of the pressure controller listed are not binding
and may be changed by the manufacturer without prior
notice in the course of further development.
The drawings and all other information regarding the
pressure controller are the property of NE-MA s.r.l.,
Druento, Italy.
This pressure controller may only be used for controlling
pumps and compressors.
This pressure controller may only be connected by an
authorised specialist.
Incorrect connection may make the pressure controlle
r
inoperable and therefore destroy it.
It is prohibited to open the pressure pipe connection!
Attention! Components are under enormous spring tension!
Warranty conditions
Müller & Vedder GdbR gives a 24 month warranty on new
devices which are installed in accordance with the
installation instructions. The warranty covers all design,
material and manufacturing defects. Further entitlements, in
particular to the payment of assembly and disassembly costs,
do not exist.
Faults and defects not covered by the warranty are
those which are due to:
1. incorrect assembly or installation
2. failure to observe the operating instructions
3. incorrect operation or load
4. external influences such as shocks, knocks and
weather conditions
5. repairs and modifications by unauthorised third parties
6. use of unsuitable accessories.
Defects occurring during the warranty period will be
eliminated free of charge either by repair or replacement.
Replacement delivery of a new device does not entail an
extension of the original warranty period.
Distribution in Germany by:
Müller & Vedder
Elektrotechnischer Vertrieb GdbR
Martin-Luther-Str. 29, 91207 Lauf
Central warehouse: Bassermannstr. 7, 70563 Stuttgart

Summary of content (1 pages)