Instructions / Assembly

5
FTF01 Rev.2 042019
Luxier
Installation
1
2
4
4-1
4. With the Tub Filler Assembly aligned in the desired
position, mark each of the 4 mounting holes from the
Mounting Flange (1) on the oor.
4-1. Use a drill with 1/4” drill bit, drill the holes 1 3/4” deep
and insert the included Anchors (2). Make sure the Anchors
are ush with the nished oor.
5. Make sure both Hot and Cold water supply hoses pass
through the 2” mounting hole with at least 1 1/4” of the
hose in the oor space.
1/2 " Supplies Hoses
Hot Cold
1 1/4”
Finished Floor
Sub-Floor
HOT
COLD
5
pipe support
1
water pipe
water pipe
6
6. Apply PTFE tape to the threads of the T-Connector (1)
and the 2 Thread Adapters. Connect the 2 adapters to the
T-Connector (1) and tighten fully. Secure pipe below oor
to oor joist with pipe supports. Connect the 2 water supply
hoses to the T-Connector (1) and use an adjustable wrench
to tighten connections. Do not over tighten the connections.