Manual

Station Settings
Station Settings allows you to set parameters specific to each station.
Use the up or down arrow keys to navigate through the menus.
Use the left and right arrow keys to advance to the next entry field on the same menu line.
Use the input dial to select values when editing.
S001 Select the station you want to edit in this field. Choose from Station 001 through the controller
maximum station count of 200.
100% If weather or other condition requires irrigation program modification, it can be easily adjusted
by changing the percent adjustment. Station operation can be reduced to 000% (Off) or
increased up to 250%. 100% represents standard operation.
Decoder Addr: Enter the decoder’s 5-digit address code that corresponds to the selected station.
Dec Sta: If using a 2 or 4-station decoder, select the decoder station to designate to the selected station.
Decoder Station Color Codes
RED = Station 1, GREEN = Station 2,
ORANGE = Station 3, BLUE = Station 4
Board: Select the correct daughter board (1 or 2) the station is connected to. Enter wire board 01 for
stations connected to the 1st daughter board and wire board 02 for the 2nd daughter board.
Disable: Use this function to disable station operation by selecting Yes from the menu. Resume station
operation by selecting No from the menu.
Set Sta as a MV: Use this function to designate the station to operate as a Master valve by selecting Yes.
Suggestion: Assign station number that will not interfere with your programming such as
100 or 200.
Assn Sta to MV: Use this function to assign a station to run with a specific master valve (Not available if the
station is designated as a Master Valve).
Sched Today: This function will display the total scheduled station runtime for the current day.
Water Today: This function will display the total station runtime that has occurred for the current day.
Is Switch: Use this function to assign the selected station to a switch. When the switch (station) is
activated, the Master Valve or Pump will not actuate.
Hold Sta: Use this function to delay operation for this station. Select the hold duration from 01–30 days,
Permanent or None. This function is useful when a specific station needs to be deactivated
without affecting any of the programs.
Cycles: Use this function to set the station cycle. When Station cycle is set to more than 1, the station’s
runtime in the program will be divide by the cycle number. Select from 1–4 cycles and
Autocycle.
With Autocycle, you can specify the maximum runtime and soak time for the station. TDC
will run the station until the maximum cycle time. TDC will then pause watering until Soak
time is fulfilled. It will repeat the process until the program’s station runtime is fulfilled.
Edit Name: Use this function to assign a name description to the station. Assign a 10-character name of
your choice, such as “shrubs” or “back lawn” to easily identify the station area.
Output Volts: Use this function to select the controller’s output voltage. Select between 15 or 20 volts DC.
Important! For proper operation, install compatible DC-latching solenoids only.
9