Manual
Alarm Conditions
All of the Alarm Conditions, when active, toggle back and forth between the two message states below.
Short Circuit Alarm
D1 Short
D2 A=0.500
Hold Opt to Clr
D2 A=0.500
• 2.0 Amp Trigger
• Shuts off and disables daughter board indefinitely.
• Motherboard LCD toggles alarm and instruction on how to re-enable the
daughter board.
• Affected daughter board’s alarm LED blinks on and off.
Thermal Alarm
D1 Thermal
D2 A=0.500
Hold Opt to Clr
D2 A=0.500
• Shuts off and disables daughter board indefinitely.
• Motherboard LCD toggles alarm and instruction on how to re-enable the
daughter board.
• Affected daughter board’s alarm LED blinks on and off.
High Current Alarm
D1 High Amp
D2 A=0.500
D1 A=1.100
D2 A=0.500
• Triggered when individual daughter board’s load current is above 1.0 Amps
for a minimum 10 seconds.
• 10 second timer is reset when below 1.0Amps.
• Does NOT shut off or disable daughter board.
• Motherboard LCD toggles alarm message and load current.
• Affected daughter board’s alarm LED blinks on and off.
Phase Current
Imbalance Alarm
D1L1 High Amp
D2 A=0.500
D1L1 A=0.750
D2 A=0.500
• Triggered when load current of one wire is 2x higher than the opposite wire
for a minimum 20 seconds.
• 20 second timer is reset when load current of one wire is no longer 2x
higher.
• Does NOT shut off or disable daughter board.
• Motherboard LCD toggles alarm message and load current.
• Affected daughter board’s alarm LED blinks on and off.
The display difference between the High Current Alarm and Phase Current Imbalance Alarm is subtle:
Notice the two-character difference in the display on the first line:
“D1” (High Current Alarm) vs. “D1L1” (Phase Imbalance).
Specifications
Fuse and Circuit Breaker
1.5A On/O Switch/Circuit Breaker – Main
Power Input
3.15A Fuse (Slow-Blow) – PCB Output
Controller
Input: 100–240 VAC, 50/60 Hz
Output: 36 VDC, 1.8A Maximum Total
Operating Temperature: -10°C to +60°C
(14°F to 140°F)
Storage Temperature: -30°C to +65°C
(-22°F to 149°F)
© 2013 The Toro Company, Irrigation Division Form Number 373-0717 Rev. C