Manual

% (Percent) Adjust
The percent adjust function allows you to fine tune irrigation programs. With weather conditions changing
constantly, Percent Adjust allows you to easily adjust your system’s schedules without modifying the program
values.
Important: The percentage settings do not override each other, instead, they multiple each other to get the effective
adjustment .
Example: Controller’s Global% is set at 150%, Program% is set at 125% and Station% is set at 90%. The effective
watering adjustment is calculated to be 1.5 x 1.25 x 0.9 = 1.68 or 168%.
Percent Adjust...
Global: 100%
Program : P01 100%
Station : S01 100%
Global will adjust from 1–250%
Program will adjust from 10–250%
Station will adjust from 0–250%
% Adjust Directions
1. Press the % Adjust key . The cursor is initially located at the Global: adjust field. Use the input dial
to adjust all scheduled watering up to 250% or down to 1%.
Note: The controller adjustment will affect all programs universally. Do not adjust the System % settings if
the adjustment is only needed to a specific program.
2. Press the down arrow to advance the cursor to the Program: field. The first entry field will be the
program selection field. Use the input dial to select the program being adjusted. Press the right
arrow key to advance the cursor to the percent adjustment field. Use the input dial to adjust
the program watering up to 250% or down to 10%. Repeat step 2 to adjust additional programs.
Note: Do not adjust the program % setting if adjustment is station specific.
3. Press the down arrow to advance the cursor to the Station: field. The first entry field will be the station
selection field. Use the input dial to select the station being adjusted. Press the right arrow key
to advance to the percent adjustment field. Use the input dial to adjust the station watering
up to 250% or down to 000%. Repeat step 3 to adjust additional stations.
Note: Adjusting the station’s watering to 000% will prevent it from running within a program. Multi-Manual
and Syringe are not affected by the % Adjustment.
Start Key
The Start key is used to execute a manual function.
Note: Pressing the Start key while the controller is idle will prompt the Manual Watering menu.
Multi-Manual Start Display Manual Syringe Start Display Manual Start Display
Program 01
Starting
03
STOP to cancel
Syringe Starting
Program 01
03
STOP to cancel
Multi-Manual
Starting
03
STOP to cancel
15