Manual
Scheduled Watering
The TDC-100/200 features 10 fully-independent resident programs. With two types of programs to select
from, you can further custom fit your irrigation programs to any landscape.
• Standard Irrigation Program will activate a station or group of stations with six start times on a daily basis. Each
station will water for the duration specified in hours, minutes and seconds. Percent adjust and maximum number
of simultaneous activate stations per program can be specified in this program.
• Grow-In Irrigation Program will activate a station or group of stations for the
length of their runtime. The program will repeat the cycle after the specified
delay time expires and will repeat continuously between the set Start and End
times. Percent adjust and the simultaneous activate stations can be specified in
this program.
To utilize these programs automatically or manually, each program must be
configured.
Standard Irrigation Program Setting:
Standard Irrigation Program example: Create Program 02 with stations 6–10
running 15 minutes each and stations 15–20 running 10 minutes each with
no percent adjustments. Set the start time at 6:30 am with five maximum
simultaneous active station.
1. Press the Scheduled Watering key . The cursor is initially located at the
program selection field. Use the input dial
to select the program
(P01–P10) you want to create or modify. For this example,
select 2.
2. Press the right arrow key to standard to the Percent Adjust field. Normally this setting will be 100%
unless weather or other condition suggest that less or more irrigation is needed. Use the input dial
to adjust the setting. For this example, no adjustment is needed.
3. Press the down arrow key to advance the cursor to the Hold: field. Use this function to suspend
program operation. Select from None, Today, 02–30 days or Permanent. For this example, select None.
4. Press the down arrow key to advance the cursor to the Type: field. Use the input dial
to
adjust the setting. For this example, set the Type to Standard.
5. Press the down arrow key to advance the cursor to the Days: field. Use the input dial
to
select the program activation interval from 01–30 days. Select 01 for everyday, 02 for every other day, 03 for
every third day and so on. The example does not call for a set interval. Leave the Days: setting to SMTWTFS.
6. Press the down arrow key to advance the cursor to the Set: field. Use the input dial
to select
from any of the preset intervals (All, Alternate days, Weekdays only, Weekends only, None or User set). To
create your own program activation interval, select Set:. Use the right arrow key to select the day of the
week you want to irrigate and use the input dial
to activate (X) or deactivate (blank) the selection.
For this example, activate M (Monday), W (Wednesday) and F (Friday) only. MWF of the 1st and 2nd week
should have an X mark under while the rest are blank.
7. Press the down arrow key to advance the cursor to the Start: field. The first entry field will indicate the
start time number. Each program can have a maximum of 24 start times. Use the input dial
to
choose the start time being created or modified. Press the right arrow key to advance to the time entry
field. Use the input dial
to select the start time in hours and minutes ( HH:MM). Repeat Step 7
for additional start times. For this example, set start time 01 to 05:45am.
(Continued to the next page)
FlowSens:03StaFlo200
Output Volts: 15
Is Switch: NO
Hold Sta : NO
Cycles : 01 times
Edit Name: 01TE020
Set Sta as a MV: NO
Assn Sta to MV: 000
Sched today: NONE
Water today: NONE
S016 100% 1STSTLAWN
Decoder Addr: 38684
Dec Sta: 4 Board: 1
Disable: No