User Manual

Pg. 14
Cooling
Sets the cooling rpm after shut down or
when starter is manually run using test
functions.
*Please note that following a failsafe
failure or flameout that the motor will not
automatically enter a cool down sequence.
This is because the ECU has no way of
knowing the status of the motor whether
flame out, crash or other.
Running Display
This menu control running parameters
RPM ACC Press “OK” to access
acceleration curve
Max RPM – Set maximum RPM
Idle – set idle RPM
Min RPM set stop RPM - if motor RPM
falls below this setting, motor will
shutdown.
MaxTemp -
Set maximum running temp.
If motor exceeds this value, ECU will
automatically limit fuel in order to
reduce the temp.
LowVolt – set low volt warning
Restart - Can be set effective or
ineffective, flame out automatically
restart or not
Restart power pump set power to pump
on restart. Normal range from 0.5 1.1
Volt