User Manual
Pg. 13
GasValve and MainValve - Set the
percentage of time of the main fuel valve
is open at beginning of the switchover
phase. This percentage will increase
automatically with RPM until arrive to fully
open when the RPM of next phase are
reached. The time where the burner valve
is open is complementary to the injector
time, so when the main valve is open at
80%, the burner is 20%. Typical value
50%-70%
Ignition RPM – Set the RPM where
ignition phase commences
Preheat RPM – Set the RPM value for
preheat phase to begin.
RPM Starter Off – Set the RPM where the
starter motor will disengage.
Learn RC
This menu is to train the transmitter to the
ECU.
Max – Throttle up, trim up
Idle – Throttle down, trim up
Min – Throttle down, trim down
LostSafeTime – set fail safe time in
seconds