User Manual
16
REPLACING SOLDERING IRON CORD
When cord is proven to be faulty follow the steps to replace the cord:
1. Followthestepsindisassemblingthehandpiece.
2. Write down or make a brief illustration of wire configuration in
thePCB.
3. Unsolder the wires connecting the hand piece PCB and cord
together.
4. Unattached the (white wire for 936 , black wire for 936A)
connectingthecordandgroundingspringtogether.
5. Detachthe PCBfromthecordbyreleasingthemetalgripslocated
atthebottomofthePCB.
6. Slideoutthemainhandle,softgrippadandtailendofthehand
piece.
7. Insertthetailendandsoftgrippadintothenewcord.
8. Insertthenewcordthoughtthemainhandle.
9. Solder the wires back into the PCB, using the proper
configurations.
10. Reattach the wires (white wire for 936 , black wire for 936A)
fromthenewcordtothegroundingspring.
11. Bend the metal on the bottom end of the PCB to grip the cord
firmly.
12. Follow “Reassembly of hand piece” procedure to complete the
process.
Note : Different models have different configurations it is critical to
have proper wire configurations clearly noted before proceeding to
the next step. (See proper connections table for reference)
9
焊铁头的维护和使用
Aoyue936 规格
SOLDER TIP CARE and MAINTENANCE
● STEPS in Calibrating the Tip Temperature
1. Pluginstationandturniton.
2. Settemperatureto400°C(750°F)
3. WaitforHeaterLEDtolightup.
4. Useanexternalsensorandplaceitonthesoldertip.
5. TakeofftherubberstopintheCALpoint.Useascrewdriver,one
thatfitstheCALhole,toadjusttheCALpoint.
Turnclockwise ‐ Toincreasetemperature
Counterclockwise ‐ Todecreasetemperature
6. Adjustuntiltheexternalsensorreads400°C(750°F).
● STEPS in Checking, Cleaning and Tinning the Tip
1. Settemperatureto250°C(482°F)
2. Afterrealtemperaturereachesthesettemperature,useadamp
spongetocleanthetipandcheckfordamages.
3. If the tip has oxidation, apply solder and wipe using the damp
sponge,repeatthesestepsuntiloxidationisremoved.
4. After cleaning,coattipwithathinlayerofsolderand setitaside
readyforthenextusage.
5. Ifthetipshowsdisfigurationorhasrustonit.Changethetip.
Neverusefileorsharproughobjectsinremovingoxidationofthetip
Temperaturecalibrationmustbedoneeverytimeyouchangethe
soldertiporchangetheheatingelement.