Data Sheet

Preliminary Data Sheet
P 5046 55
> Sensitivity:
standard
> Protective Coating:
without topcoat
> Resistance:
very good stability against environmental influences
> Archivability:
10 years*
> Special Features:
Physical Properties Value Unit Test Method
Base Weight 55 ± 4 g/sqm ISO 536
14.6 ± 1.1 lbs 17 x 22 - 500
Caliper 60 ± 5 µm ISO 534
2.4 ± 0.2 mil
Smoothness (Bekk) > 260 sec ISO 5627
Brightness (R 457) > 87 % ISO 2469
Tensile Strength (MD | CD) > 47 | > 11 N/15mm ISO 1924/2
Opacity > 85 % ISO 2471
ende
Resistance Condition Image Contrast
Heat
60°C / 24h
> 90% > 85%
Humidity
40°C / 90% r.h. / 24h
> 90% > 90%
Light incl. UV 10,000 kJ / m² > 85% > 80%
Lanolin hand cream 4h room temp. > 65%
Ethanol (25 vol %) dipped 20min. / 24h room temp. > 30%
Plasticizer Tesa Document 57331
24h room temp. > 45%
Water dipped 20min. / 24h room temp. > 65%
ende
Sensitivity
Densitometer Techkon
* specific handling & storage conditions have to be observed Trial P504655 Valid from 01.06.2016 | Subject to alterations
HiTec Paper.
Mitsubishi HiTec Paper Europe GmbH | Niedernholz 23 | 33699 Bielefeld | Germany
Tel. +49 521 2091-535 | sales.mpe@mitsubishi-paper.com | www.mitsubishi-paper.com
Bisphenol A-free
0,0
0,2
0,4
0,6
0,8
1,0
1,2
1,4
1,6
1,8
2 4 6 8 10 12 14 16
OPTICAL DENSITY [ODU]
ENERGY [mJ/mm2]
DYNAMIC SENSITIVITY
Printer-Lab(Gebe)
0,0
0,2
0,4
0,6
0,8
1,0
1,2
1,4
1,6
1,8
60 70 80 90 100 110 120 130 140
OPTICAL DENSITY [ODU]
TEMPERATURE [°C]
STATIC SENSITIVITY
Toyoseiki No 884