Installation Guide

55
Controller to Battery Fuse = Current Rating of Charge Controller
Ex. 30A ViewStar CC = 30A from Controller to Battery
Be careful not to short the battery. Reverse polarity connection will damage the
charge controller and the resulting damage will not be covered by warranty.
WARNING
4. The fuse between controller and battery should be the current rating of the controller. Once
the fuse is properly sized, ensure that all connections were made properly, and that there are
no loose connections present. Finally, insert the fuse into the fuse holder.
The controller
should power on.
3. Once the fuse holder is in place, don’t attach a fuse just yet. Connect the bare stranded
portion of the cable to the
positive (+)
battery terminal on the charge controller.
5. If opting for
no in-line fuse
, connect the bare stranded portion of the cable to the
positive
(+)
battery input terminal on the charge controller directly from the
positive (+)
battery post,
bypassing the fuse holder.
The controller should power on.
Maxi blade fuse