SERVICE AND STORAGE
Infrequent Service
If the unit is used infrequently, difficult starting 
may result. To eliminate hard starting, follow 
these instructions:
1. Run the generator at least 30 minutes every 
 month.
2. Run the generator, then close the fuel shut-off 
 valve and allow the unit to run until the engine 
 stops.
3. Move the engine switch to the "OFF" position.
5. Pour about one teaspoon of engine oil through 
 the spark plug hole, pull the recoil starter 
 several times and replace the plug. Then pull 
 the starter until you feel the piston is on its 
 compression stroke and leave it in that 
 position. This closes both the intake and 
 exhaust valves to prevent the inside of the 
 cylinder from rusting.
6. Cover the unit and store in a clean, dry place 
 that is well ventilated away from open flame 
 or sparks.
Long Term Storage
When the generator set is not being operated 
or is being stored more than one month, follow 
these instructions:
1. Replenish engine oil to upper level.
2. Run the generator, then close the fuel shut-off 
 valve and allow the unit to run until the engine 
 stops.
3. Move the engine switch to the "OFF" position.
4. After the unit has cooled, drain gasoline from 
 fuel tank, fuel line and carburetor.
NEVER USE WATER TO CLEAN GENERATOR. 
Pull starter handle until resistance is felt, leaving 
handle in that position. 
Store generator in a well ventilated, low humidity 
area.
•
•
NOTE: We recommend always using a fuel 
stabilizer. A fuel stabilizer will minimize the 
formulation of fuel gum deposits during 
storage. The fuel stabilizer can be added to 
the gasoline in the fuel tank, or into the 
gasoline in a storage container.
WARNING
Generator exhaust contains odourless and
colourless carbon monoxide gas.
To avoid accidental or unintended ignition of 
your generator during periods of storage, the 
following precautions should be followed:
When storing the generator for short or 
extended periods of time make sure that the 
Engine Switch and the Fuel Valve are set in the 
OFF position.
ALWAYS connect the positive (+) battery cable 
(red boot) first when connecting battery cables.
ALWAYS disconnect the negative (-) battery 
cable (black boot) first when disconnecting 
battery cables.
NEVER connect the negative (-) battery cable 
(black boot) to the positive (+) post on the 
battery.
NEVER connect the positive (+) battery cable 
(red boot) to the negative (-) post on the battery.
NEVER touch both battery posts simultaneously.
NEVER place a metal tool across both battery 
posts.
ALWAYS use insulated or nonconducting tools 
when installing the battery.
To avoid electric shock:
Battery Replacement On Remote
Lithium Battery
1. Loosening and remove cover screws.
2. Remove the cover.
3. Remove the depleted batteries and insert 
 two new CR2016 lithium batteries with the 
 “+” terminal facing up.
4. Close the remote cover and tight the screws.
English Customer Service: 1-844-FIRMAN1