Replacement Part List
Page 22
English Customer Service: 1-844-FIRMAN1
WARNING
If a cover is used, do not install until unit has cooled.
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or
explosion resulting in death, serious injury
and/or property damage.
Flip the engine switch to“OFF”(O) position.
5. Turn the fuel valve to the “OFF”(O) position.
STOP
3. Electric Start and Recoil Start Operations
4. Flip the battery switch on "OFF"(O) position.
STOP
THE BATTERY SWITCH ALWAYS SHOULD BE IN 
"OFF"(O)  POSITION  AT  THE  END  OF  USE  TO 
PREVENT BATTERY DRAIN.
DO NOT stop engine by moving choke control
to “START” position.
Important: Always ensure that the Fuel Valve 
and the Engine Switch are in the “OFF” position 
when the engine is not in use.
If the engine will not be used for a period of two 
weeks or longer, please see the Storage section 
for proper engine and fuel storage.
Low Oil Shutdown
If the engine oil drops below a preset level, an 
oil switch will stop the engine. Check oil level 
with dipstick.
If oil level is between LOW and HIGH mark on 
dipstick:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is 
 corrected.
If oil level is below LOW mark on dipstick:
1.Add oil to bring level to HIGH mark.
2.Restart engine and if the engine stops again 
 a low oil condition may still exist. DO NOT try 
 to restart the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is 
 corrected.
Do Not Overload Generator
Overloading a generator in excess of its rated 
wattage capacity can result in damage to the 
generator and to connected electrical devices.
To prolong the life of your generator and 
attached devices, follow these steps to add 
electrical load:
1. Start the generator with no electrical load 
 attached.
2. Allow the engine to run for several minutes 
 to stabilize.
3. Plug in and turn on the first item. It is best to 
 attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.