SDS
Safety Data Sheet
According to HCS-2012 APPENDIX D TO §1910.1200
V
ersion: 1.0/EN Revision date: 28-Dec-2016
Product name: Lithium Ion Polymer Battery Printing date: 28-Dec-2016
-- Page 8 / 12 --
Skincontact: Specific test data for the substance or mixture is not available. Corrosive.
(basedon components). Causesburns.May be absorbedthroughtheskin
inharmfulamounts.Harmfulincontactwithskin.
Eyecontact: Specific test data for the substance or mixture is not available. Causes
burns.(basedon
components).Corrosivetotheeyesandmaycausesevere
damage including blindness. Causes serious eye damage. May cause
irreversibledamagetoeyes.
ComponentInformat ion
ChemicalName OralLD50 DermalLD50 InhalationLC50
Graphitepowder
7782‐42‐5
>10000mg/kg(Rat)
Nickel
7440‐02‐0
>9000mg/kg(Rat)
Aluminumfoil
7429‐90‐5
>15900mg/kgbw(rat) >0.888mg/L/4h(rat)
Copper
7440‐50‐8
>2500mg/kgbw(rat) >2000mg/kgbw(rat) =1.03mg/L/4h(rat)
(b)Informationontoxicologicalcharacteristics
Symptoms Erythema (skin redness). Burning. Maycause blindness. Coughing and/ or
wheezing.Itching.Rashes.Hives.
(C) Delayedandimmediateeffectsaswellaschroniceffectsfromshortandlong‐termexposure
Sensitization Noinformationavailable.
MutagenicEffects Noinformationavailable.
Carcinogenicity Thetablebelowindicateswhethereachagencyhas
listedanyingredientas
acarcinogen.
ChemicalName ACGIH IARC NTP OSHA
LithiumCobaltOxide
(CoLiO2)
12190‐79‐3
A3 Group2B X
Nickel
7440‐02‐0
Group2B ReasonablyAnticipated X
ACGIH(AmericanConferenceofGovernmentalIndustrialHygienists)
A3‐AnimalCarcinogen
IARC(InternationalAgencyforResearchonCancer)
Group2B‐P ossiblyCarcinogenictoHumans
NTP(NationalToxicologyProgram)
ReasonablyAnticipated‐ReasonablyAnticipatedtobeaHumanCarcinogen
OSHA(OccupationalSafetyandHealthAdministrationoftheUSDepartmentofLabor)
X‐Present
ReproductiveToxici ty Noinformationavailable
STO T‐singleexposure No
informationavailable
STO T‐repeatedexposure Causesdamageto organsthroughprolongedorrepeated exposure. Based
on classification criteria from the 2012 OSHA Hazard Communication
Standard(29 CFR 1910.1200), this producthas been determined to cause