Manual
Menu: Station Amps – Use this menu item to review each of the station’s last recorded voltage
amperage, nominal amperage value, tolerance value, alarm events, pump
nominal amperage value. Use the Input Dial to scroll through the
available stations. Use the Down arrow to scroll down to the data fields.
You can reset the Nominal amperage value within this menu item by selecting
Reset using the Input Dial and pressing the Down arrow to
activate.
You can modify the Tolerance (Tol +/–) amperage value within this menu item by
using the Input Dial to select the desired value.
You can also enable or disable the station within this menu item. Enabling or
disabling the station in this screen will also be reflected in the Station Setting’s
Disable setting. Enabling the station will also clear any corresponding over/under
current alarms for the station. To disable, select Yes in the Disable field using the
Input Dial . To enable the station, select No in the Disable field using
the Input Dial.
Menu: Send Ctrl Code – Use this menu item to send Control Codes. These control codes are set in
SitePro. To send a control code, navigate to the Code field using the Down arrow
and use the Input Dial to select the code you want to send.
Press the Start key to send.
Menu: VA Monitor – This menu item allows you to monitor the satellite’s amperage, voltages and
temperature in real-time. This allows you to troubleshoot the satellite’s internal
circuit voltages.
Menu: Event Codes – This menu item will display the satellite’s Event Code log. You can clear the log
from this option. Navigate to the Clear field using the Down arrow , select
Yes using the Input Dial and press the Down arrow to activate.
Menu: Link Settings – Use this menu item to view the satellite’s communication settings. Parameters
can not be edited here.
25