Manual

Station Settings
Station Settings allows you to set parameters specific to each station.
Use the Up or Down Arrows to navigate through the menus.
Use the Left and Right Arrow Keys to advance to the next entry field on the same menu line.
Use the Input Dial to select values when editing.
S01 Select the station you want to edit in this field. Choose from Station 01 through the satellite
maximum station count of 64.
100% If weather or other condition requires irrigation program modification, it can be easily adjusted
by changing the percent adjustment. Station operation can be reduced to 000% (Off) or
increased up to 900%. 100% represents standard operation.
Sched Today:This menu item will display the total scheduled station runtime for the current irrigation day.
Water Today:This menu item will display the total station runtime that has occurred for the current
irrigation day.
Note: Runtime resulting from a station that is manually activated via the output hardware
switch will not be captured.
Water Yestr: – This menu item will display the total station runtime that occurred for the previous
irrigation day.
Note: Runtime resulting from a station that is manually activated via the output hardware
switch will not be captured.
Disable: Use this menu item to disable station operation by selecting Yes from the menu. Resume
station operation by selecting No from the menu. Enabling a station (disable = no) will clear
corresponding station alarms that resulted from over/under current conditions.
Hold Sta: Use this menu item to delay operation for this station. Select the hold duration from
01–30 days, Permanent or None. This option is useful when a specific station needs to be
deactivated without affecting any of the programs.
Is Switch: Use this menu item to assign the station to a switch. When the switch (station) is activated, the
Master Valve or Pump will not actuate. The output will remain as 24 VAC
Cycles: Using this menu item will result in additional start times without increasing the station runtime.
Cycles will automatically divide the corresponding station runtime by the Station Cycles value
and execute each resulting cycles after satisfying the program soak duration. Select from 01
(normal operation) through 04 cycles or you can select Autocycle. When selecting Autocycle,
the Max Cycle duration and Auto Soak duration must be entered. Autocycle will then run the
station up to the Max Cycle duration, wait for the Auto Soak duration to expire, then initiate
another cycle until the total station runtime is completed.
14