Specification
W415-1755 / 05.03.17
EN
14
installation
Prepare rough in framing following the recommended dimensions, see Figure 1.
Select a location that is not prone to moisture and is located at 36” (91.4cm) away from combustible materials as
curtain drapes, furniture, bedding, paper, etc.
1. Once the rough opening has been prepared and the power has been routed to the right side of the recess,
the appliance may be installed.
2. The electrical connection must be made prior to placing the appliance into position, see “hard wiring
installation” section.
29”
(73.6cm)
29”
(73.6cm)
41”
(104.1cm)
23”
(58.4cm)
C
B
A
F
Floor
or mantel base
Fig.1
4.5.2 installing the appliance into the wall
Fig.1
FIREPLACE / MANTEL OPENING DIMENSION REQUIREMENTS
3-SIDED TRIM 4-SIDED TRIM
A
Min. 9” (22.9cm) Min. 9” (22.9cm)
B
Min. 23” (58.4cm) / Max. 35” (88.9cm) Min. 23” (58.4cm) / Max. 35” (88.9cm)
C
Min. 17 1/4” (43.8cm) / Max. 22 1/2” (57.1cm) Min. 17 1/4” (43.8cm) / Max. 22 1/2” (57.1cm)
F
Min. 0” Min. 6.5” (16.5cm)