MINI HIGH SPEED DOME CAMERA User Manual Power Supply DC 12V Factory Configuration: PELCO-D protocol, Baud rate 2400, Address code 1 ※Please read carefully before using this manual
Catalogue Chapter 1 Product Summarize………..………….…………….………….………….………….………….……………2 1 . 1 Te c h n i c a l P a r a m e t e r s … … … … … … . … … … … . … … … … … . … … … … . … … … … . … … … … . … … … … . … … … … … . 2 1.2 Function description………………………………………………….………….………….………….……….……….2 C h a p t e r 2 E q u i p m e n t i n s ta l l a t i o n … … … … … . … … . … … … … … … … … . … … … … . … … … … . … … … … . … . . … … … … 5 2.1 DIP sw itch settings………………......................................... ……….………….………….………….
Chapter 1 Product Summarize 1.1 Technical Parameters (standard) Model number 4 INCH MINI HIGH SPEED DOME CAMERA Optical focus 10X Image sensor 1/3"CCD Signal mode PAL / NTSC Resolution Optical focus Presets 480TVL / 540TVL / 650TVL/ 700TVL Manual/Auto, adapt high performance DSP to realize full digital high continuous focusing function. 256 Pattern scan 4 groups, each can record 100 actions Cruise scan 30 presets can join cruise, can setting the presets’ residence time.
Ball cover dimension Material Work environment 4 inch optical glass cover Aluminum shell, waterproof IP66 -20℃~+50℃(select temperature control accessories), <95%RH 1.2 Function description 1. Set address coding, baud rate, control protocol Any operation commands the camera has its own objectives address coding, baud rate, control protocol, a single camera only to respond with its own address coding, baud rate, control agreement under the operation of the command.
achieve the full 180 ° continuous vertical surveillance. 5. Set and call preset position Preset function is the current state of the ball under the PTZ function of the horizontal angle, tilt angle and camera lens focal length, etc. position parameters stored in memory, you need to call these parameters can be quickly and PTZ cameras will be adjusted to that location.
e. Targets moving too fast; f. Large area targets, such as walls; g. Objectives are too dark or inherently ambiguous. 7. Aperture Control Users can control the keyboard to manually adjust the aperture size to get the required picture brightness. 8. Auto Backlight Compensation When the backlight compensation function is open, the camera lens in the light background can be automatically targets the more the dark luminance compensation.
Pattern scanning machines to run the ball through the menu, the trajectory is stored down by power-on action, free movement, alarm linkage, etc. to call the stored scan line. 13. Continuous scan Just an external command or through a power-on action, free movement, alarm linkage, etc. to call, can make the ball machine horizontal direction to a certain speed the cycle of continuous scanning. 14. Batch Scanning Just an external command or through a power-on action, free movement, alarm linkage, etc.
Control protocol ON OFF PELCO-D OFF ON PELCO-D/P ON ON PELCO-D/P OFF OFF 9600 ON ON 9600 OFF ON 4800 ON OFF 2400 (BPS) 8-bit DIP switch is used to set the dome camera address coding. Address set binary mode can be set to a total of 256 different dome camera address coding, see coding table address.
10 OFF ON OFF ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF … … … … … … … … … 246 OFF ON ON OFF ON ON ON ON 247 ON ON ON OFF ON ON ON ON 248 OFF OFF OFF ON ON ON ON ON 249 ON OFF OFF ON ON ON ON ON 250 OFF ON OFF ON ON ON ON ON 251 ON ON OFF ON ON ON ON ON 252 OFF OFF ON ON ON ON ON ON 253 ON OFF ON ON ON ON ON ON 254 OFF ON ON ON ON ON ON ON 255 ON ON
2.
2.
Chapter 3 System OSD menu settings 3.1 Power-On Self-Test When power is connected to the dome camera, the camera in horizontal and vertical direction movement, the screen will appear system-related information, the dome camera self-test to complete the following diagram. PTOL: PELCO-D COMM: 2400,N,8,1 ADDR: 1 Display: PELCO-D protocol、Baud Rate 2400、Address code 1 3.2 Preset point setting and calling 3.2.
3.3 Preset point function table: Dial the 95th Presets nd Dial the 82 Presets Enter Main menu.
CRUISE SETTING IR SETTING Preset point cruise setting; In the table 3-7. Infrared light setting; In the table 3-8. DISPLAY SETUP Screen display setting. In the table 3-9. RESTORE FACTORY DEFAULT Restore the factory default setting. REBOOT System restart, the dome camera to power on reset. SYSTEM EXIT Exit the OSD menu setting. TABLE 3-1 MAINMENU 3.5 SYSTEM INFORMATION COM 2400,N,8,1 ADDRESS PROTOCOL 1 PELCO-D PRESETS 256 SOFTWARE VERSION V5.
ADDR SETTING ADDR TYPE Menu function descriptions Divides HARD and SOFT; select the SOFT can directly determine the dome camera address. HARD ADDR SOFT 1 ADDR HARD 1 Within 1~254. BACK Returns to main menu. RESET To restore the default. EXIT Exit the menu setting. Note: Can’t mix up the soft and hard address settings, would create the dome camera out of control, setting reboot to be valid. TABLE 3-3 ADDR SETTING 3.
RANDOM SCAN SPEED 16 Set the intermittent scan speed of the dome camera. Within 1 (Slowest) ~32 (Fastest). BACK Return to the main menu. EXIT Exit the menu setting. TABLE 3-4 3.7.1 (setting area scan) Setting area scanning range, specific operations as shown in the following table: FRAME SCAN Menu function descriptions SET SCAN POSITION Set area scan position. In the table 3-4-2. CLEAR FRAME SCAN Clear area scanning setting. (Clear left and right limit position).
RIGHT LIMIT POSITION IRIS OPEN TO CONTINUE Shake the joystick to select the right limit position; Press IRIS+ button to confirm and return to the table 3-4. TABLE 3-4-3 SET THE RIGHT LIMIT POSITION 3.7.3 CLEAR FRAME SCAN (Clear area scan location) CLEAR FRAME SCAN IRIS OPEN TO CONTINUE Press IRIS+ to clear the left and right limit position and return to the table 3-4. TABLE 3-4-4 CAMERA SETTINGS MENU 3.7.4 The dome camera is powered on, didn’t receive any instructions to perform action.
TABLE 3-4-5 POWER UP MENU 3.7.5 In the idle time, the dome camera doesn’t receive any instructions to perform an action. Idle movement parameters as shown in the following table: PARK ACTION NONE AUTO SCAN RANDOM SCAN FRAME SCAN Menu function descriptions Do not perform any action. Perform continuous scanning action. Perform intermittent scanning action. Perform area scanning action. (It will come into effect after the SET FRAME SCAN is set). FRESET 1 Arrive the First preset point.
PATTERN NUMBER 1 Select pattern number, within 1~4. PROGRAM PATTERN CLEAR CURRENT PATTERN CLEAR ALL PATTERN To select pattern scan line; Operations shown in the table 3-5-1. Clear current pattern scan line. Clear all the pattern line. BACK Return to the previous menu. EXIT Exit the menu setting. TABLE 3-5 PATTERNS 3.8.
Languages Chinese/English Multiples Display ON/OFF AGC 180 Backlight compensation ON/OFF Shutter setting AUTO Focus setting AUTO Brightness setting 110 Sharpness Setting 013 Day& night switch AUTO Negative Set OFF Lens Set OFF Default setting OFF TABLE 3-6 CAMERA SETTINGS 3.10 (Preset points, cruise settings) CRUISE Menu function descriptions DWELL TIME[SECS] PRESET LIST 1 ON 1234567890 1111111111 6 1 0 OFF PRESET [1-10] Cruise waiting time between preset points.
BACK Return to the previous menu. EXIT Exit the menu setting. TABLE 3-7 CRUISE SETTING MENU 3.11 (IR speed dome Special function) IR SETTING IR MODE Menu function descriptions AUTO ON: IR light is forced to open; OFF: Infrared light is forced to close; AUTO: IR light is switch automatically. IR ON SENS 250 Light intensity of IR light is open, within 81~254. IR OFF SENS 230 Light intensity of IR light is close, within 81~254. BACK Return to the previous menu.
Chapter 4 Simple troubleshooting and maintenance 4.1 Simple Troubleshooting Table Failure Electricity without action, no images, light does not shine.
Blur IR control of a high-speed dome camera non-stop or delay Power is not enough Replace Manual focus on the state Operation of any infrared high speed dome camera or call a preset point Power is not enough high-speed Dome Replacement to meet the requirements of the power supply, it is best to power on the high-speed dome camera in the vicinity Check control of the most distant high-speed dome camera match whether to join the resistance The most far away from the control of the ball-type cameras b
paid maintenance services. (B): The dome camera repair response time 1. Users will be sent to the company from the date of product, 24-hour response service. 2. Customers return products to our company, please advance with my company-related contact, and then returned to our company products. Otherwise, the situation appears not timely maintenance by the user themselves.
The following conditions will not be free of charge Warranty: 1. Due to normal wear and tear caused by periodic inspection, maintenance, repair or replacement parts. 2. As the fall, extrusion, soaking, damp, and other man-made damage. 3. Because of flood, fire, lightning and other natural disasters or force majeure of the factors that damage. 4. By non-authorized repair centers repair the machine off. 5. Listed above, if changes to the relevant provisions shall prevail.