Manual

3
Surge Board Outputs
17
18
19
20
21
22
23
24
IN 1
IN 2
IN 3
IN 4
IN 5
IN 6
G
12V
Terminals
Terminals Explained
Sensor board
Surge board
Label Description
17-24 Station outputs.
(These numbers can vary.)
IN 1 Pressure Sensor Input
IN 2
Flow, Rain, or Status Sensor Input
IN 3
Flow, Rain, or Status Sensor Input
IN 4
Flow, Rain, or Status Sensor Input
IN 5
Flow, Rain, or Status Sensor Input
IN 6
Flow, Rain, or Status Sensor Input
G
12 V Ground
12V 12 V DC Output
The Lynx Smart Satellite sensor (LSSS) input board can
accomodate a wide variety of sensors: pressure, ow, rain,
status, and temperature.
While we strive to support all sensors, documenting the
installation procedure for every available sensor is not
possible. If the below installation steps do not work,
consult the documentation that shipped with your sensor.
These instructions assume the specied sensor is already
installed in your irrigation system and cables already run to
the controller.
For all sensor installation
procedures, turn o󰀨 or remove
power from the controller.
Pressure Sensor
Toro sells a pressure sensor kit (part number PRESS200-
SEN-KIT), composed of a 6’ long sensor cable and a
pressure sensor.
Steps
1. At the LSSS board, secure the pressure sensor’s black
lead to screw IN 1 and white lead to screw 12V
(see Terminals Explained illustration above).
2. At the sensor, insert the wire plug into the adapter of
the pressure sensor. Be
sure the notch is aligned
with the notch clip (see
illustration, right).
The pressure sensor
ships with a six foot
long wire. If a longer
wire is needed, Toro
species Belden part
#8780, a spool of 16
AWG stranded tinned
copper conductors, PVC
insulation, twisted pair,
tinned copper spiral
wrapped sheild, PVC
jacket.
notch
notch
clip
Sensor Installation