Product Literature
If the satellite has an active running program, the display will read:
Sun 5/15/16 02:31 pm
Sat# 001-001 Sec: 57
Day Change: 12:00am
Running 01 programs
P01 Sta01 00:09:46
P02 Sta02 %00:05:00
P03 Sta03D 00:05:00
P04 Sta10P 00:12:00
P05 Soak12 00:01:32
Man Sta21 00:10:00
Man Sta22S 00:10:00
Indicates Station 01 of Program 01 is active with 9 mins and 46 secs of runtime.
The % symbol indicates that station 02 has been percent adjusted.
The “D” symbol indicates that station 03 is disabled.
The “P” symbol indicates that station 10 is paused.
“Soak” indicates that station 12 of program 5 is active and in soak transition.
“Man” indicates that station 21 was manually activated.
The “S” symbol indicates that station 22 is stacked.
Note: Program stacking occurs when the satellite is running a program where the maximum simultaneous station
limit is surpassed. Additional scheduled programs will be stacked (delayed) until an available station can be
activated.
Start Key
Press Start to execute a manual function. Use the Input Dial to select M-Manual, Syringe, Start
Prog. Press Up or Down
to navigate between parameters. Use Input Dial to select the
correct values to each parameters. Press Start
to activate.
Note: Pressing the Start key while the satellite is idle will prompt the Manual Watering menu.
Multi-Manual Start Display
Manual: M-Manual
Sta#: 01-02 00:05:00
Sta#: ----- --:--:--
Simult: 03
Press to water
M-Manual
Multi-Manual
Starting
03
Press to cancel
Manual Syringe Start Display
Manual: Syringe
Runtime: 02 min
Program: 03
Press
to water
Syringe
Syringe Starting
Program 01
03
Press
to cancel
Manual Start Program Display
Manual: Syringe
Program: 16
Press to water
Start Prog
Program 01
Starting
03
Press to cancel
9