Product Literature
Radio Specifications
Equipment Type – Digital Data radio
Frequency Band – UHF
RF Output Power – 0.5 to 5.0 watts, Programmable
Current Consumption:
Standby (Muted) – < 65 mA
Transmit 2 watts RF power – < 1.0A
FCC License: FCC ID# Pending
Fuse & Circuit Breaker Specifications
Power Supply:
1.5A On/Off Switch/Circuit Breaker – Main Power Input
3.2A Fuse (Slow-Blow) – Field Output
4.0A Circuit Breaker – Control Functions (Faceplate)
Output Board : 3A Fuse
Communication Board :
0.5A Fuse – Communication Line Protection
8A Fuse – Common Line Protection
0.5A Fuse – Pump Line Protection
Pump/Common & Communication Surge Protection Module (optional): 1A Fuse
Satellite Controller Specifications
Line Voltage: 115-120 or 230-240 VAC 50/60 Hz (switchable), 130 VA or 100/200 VAC 50/60 Hz
Current Draw (no load): 0.21A @ 115-120 VAC, 60 Hz or 0.10A @ 230-240 VAC, 50 Hz
Current Draw (no load): 0.46A @ 100 VAC, 50 Hz or 0.23A @ 200 VAC, 50 Hz
Current Draw (maximum load): 0.91A @ 115-120 VAC, 60 Hz or 0.45A @ 230-240 VAC, 50 Hz
Current Draw (maximum load): 0.99A @ 100 VAC, 50 Hz or 0.51A @ 200 VAC, 50 Hz
Current Load (based on available 24 VAC)
Maximum Current Available for Load: 3.0A (72 VA)
Maximum Load Per Station: 0.75A (18 VA)
Maximum Load Per Pump/Master Valve: 1A (24 VA)
Operating Temperature: -10°C to +60°C (14°F to 140°F)
Storage Temperature: -30°C to +65°C (-22°F to 149°F)
3