Product Literature
Set Amp Tol: – Sets current (Amps) tolerance. The Lynx Smart Satellite will
Set Amp Tol : No
OvrAmpStaDis: Yes
Language
: English
Clock Set : 8:45am
Clock Mode : Am/Pm
Date Mode : MMDDYY
Date: 01/08/12 Sat
Day Change : 12 am
CSG Address : 001
Sat Address : 001
Sta Delay : 01 Sec
Max Sim Sta : 06
Meas Units : English
Set Passwrd : ****
Display Adj :
No
use this value to determine if an under or over current event.
OvrAmpsStaDis: – (Over Amperage Station Disable) When set to Yes, Lynx
Smart Satellite will disable the offending station from
activating during an over current event. You must clear
the alarm to reactivate the offending station. To clear the
alarm, press Station Settings
, then press Down
to select Clr Alarm. Use the Input Dial
to
select Yes, the press Up or Down
to activate.
Enable Sta’s: – Resets all disabled stations with one execution.
This function will also clear all station alarms related to
under/over current conditions. Select Yes All using the Input Dial
and press Up
or Down
to activate. Select No to cancel. Individual stations can be enabled/
disabled by using the Disable function within the Station Settings menu.
Language: – The default language is English. Use this function to select your preferred language from
English, Spanish, French, Italian, Chinese, Japanese and Korean.
Clock Set: – Sets the current time. Press Left or Right
to select between the Hours and
Minutes fields, then use the Input Dial
to modify the values.
Clock Mode: – Select the clock mode from either Am/Pm (12-Hour) or 24-Hour format.
Date Mode: – Select the date mode from either Month-Day-Year (MMDDYY) or Day-Month-Year
(DDMMYY) format.
Date: – Sets the current date. Press Left or Right
to select between the Month, Date and
Year fields, then use the Input Dial
to modify the values.
Day Change: – Sets the “day change” time. The “day change” is the specified time that the satellite will
advance the date. The default day change is 12:00 am. Day change is used to determine the
active days when running programs as well as recording station activity for course reports.
CSG Address: – Sets the CSG (Central Satellite Group) address. Lynx and SitePro Central Controller use this
address to identify different satellite groups.
Identify all satellites that can be grouped together and assign them with the same CSG
address. When Lynx or SitePro Central Controller sends out a command to that CSG
address, all the satellites within that group will receive and execute the command.
Sat Address: – Sets the satellite address. Each satellite must be given a unique satellite address. Lynx and
SitePro Central Controller use this address to identify individual satellites when sending
satellite specific commands.
Sta Delay: – Sets the satellite’s station delay. The station delay determines the wait time before the next
station is activated after a station has concluded its watering cycle. This time delay is used to
allow the system to normalize between station activations.
Max Sim Sta: – Sets the maximum number of simultaneously operating stations. This threshold will be applied
to all programs and manual irrigation functions. Each program can then be set with a lower
limitation if necessary.
Note: Simultaneous setting in the Watering Schedule can not exceed the Satellite Settings.
Example: The Smart Satellite’s maximum simultaneous stations setting is set to 7, which
means the satellite will not allow more than 7 stations to turn on at the same time. All
programs in the satellite will adhere to the 7 maximum active stations and each can be
adjusted with a lower limit (6, 5, 4, etc.).
Meas Units: – Sets the satellite’s units to English (U.S. Standard) or Metric units.
Set Passwrd: – Sets a 4-digit password. When set, the password needs to be entered every time the station
and satellite settings are modified. To deactivate, set the password to 0000.
Display Adj: – Adjusts the contrast of the LCD screen. Use the Input Dial
to darken or lighten
the text display.
13