Product Literature
Unit Settings
Unit Settings allows you to set satellite parameters such as Time, Date and Language.
Press Up or Down
to navigate through the menus.
Comm Mode : Central
Hold All : None
Hold Rain : None
Reset Prg’s : No
Reset Sta’s : No
Reset Unit : No
Enabl Sta’s : No
Reset Amps : No
Central
Press Left or Right to navigate to the next entry field.
Use the Input Dial to select values when editing.
Comm Mode: – Select the satellite mode of operation between Central,
Local or Off mode.
Hold All: – Suspends all scheduled watering for all stations and switches. You can select the duration of
suspension for Today–30 days, Permanent or None using the Input Dial
.
Hold Rain: – Suspends all scheduled watering for all stations. Output terminals assigned as switches are
not affected by the suspension. You can select the duration of suspension for Today–30 days,
Permanent or None using the Input Dial
.
R eset Prg’s: – Resets all satellite irrigation program by selecting Yes. Use the Input Dial
to
select Yes, then press Up or Down
to activate. The following will display:
Reset All Programs
to defaults
05
Press to escape
All program data will be erased after a successful reset.
Reset Sta’s: – Resets all station settings by selecting Yes. Use the Input Dial
to select Yes, then
press Up or Down
to activate. The following will display:
Reset All Stations
to defaults
05
Press
to escape
All station settings will be erased after a successful reset.
Reset Unit: – Resets the satellite settings by selecting Yes. Use the Input Dial
to select Yes,
then press Up or Down
to activate. The following will display:
Reset Unit
to defaults
10
Press
to escape
After the 10-second countdown, the satellite will reboot.
Resetting the unit will erase all user-defined program data and configuration values in the
satellite’s memory.
Reset Amps: – Resets all the station’s nominal current (Amp) to 0.00. The Lynx Smart Satellite measures the
current draw for each stations during the initial activation or by performing a Setup Amps
function. The satellite will save these values as the nominal values. The satellite will compare
the current during activation to the nominal values to determine if an under or over current
event occurred.
Setup Amps: – Sets the nominal current for each stations. When activated, the Lynx Smart Satellite will
momentarily activate each station and measure the current draw. The satellite will the save
these values as the nominal values. The satellite will compare the current during activation to
the nominal values to determine if an under or over current event occurred.
12