Datasheet
Auxiliary Circuits
Feedforward Compensation
for Greater Inverting Slew Rate
²
Compensation for Minimum Settling
²
Time
²
Slew rate typically 150V/ms.
*Balance circuit necessary for
increased slew.
²
Slew and settling
time to 0.1% for a
10V step change
is 800 ns.
TL/H/7766– 8
TL/H/7766– 9
Offset Balancing Isolating Large Capacitive Loads Overcompensation
TL/H/7766– 12
TL/H/7766– 10
TL/H/7766– 11
Typical Applications
Fast Voltage Follower*
*Do not hard-wire as voltage
follower (R1
t
5kX)
TL/H/7766– 13
Integrator or Slow Inverter
C
F
e
Large
(C
F
t
50 pF)
TL/H/7766– 14
*Do not hard-wire as integrator or slow inverter; insert a
10k-5 pF network in series with the input, to prevent oscillation.
6