User manual
Dépistage d’anomalies
Avec l’alarme anti-débordement vous avez fait l’acquisition d’un
produit fiable.
Pourtant, il est possible que des problèmes ou des dérangements
surviennent.
C’est pourquoi nous vous décrivons ci-dessous comment corriger
quelques-uns des défauts possibles :
Défaut Cause possible
Pas de bip sonore lors du Est-ce que les piles sont
test de fonctionnement, pas usagées?
de signal d’alarme. Vérifiez l’ètat des piles..
Aucun signal de débordement Est-ce que le palpeur est en-
d’eau ou signalisation pas crassé ?
fiable. Nettoyez-le comme décrit dans le
chapitre «Entretien/Nettoyage».
30
A use other than the one described above causes damages to the
product. Moreover, this involves dangers, such as e.g. short-circuit,
fire, electric shock etc. No part of the product may be modified or
rebuilt!
The safety instructions must be observed!
Product description
The overflow protection device is battery-powered and can thus be
used absolutely safely in a bathroom environment. A water level sen-
sor is attached to the overflow protector which features 2 metallic
contacts for water level detection and connecting cable 150 cm in
length. The sensor must be mounted at the desired maximum water
level of the particular water container on that side of the container
which is filled. If now the water rises up to this level, the water brid-
ges the two metal contacts and the overflow protector immediately
issues an acoustic alarm. Additionally, an isolated switching contact
for connecting further indication devices can be plugged in (adapting
cable supplied).
For power supply of the device 3 batteries of the type AAA are re-
quired (supplied).
Safety instructions and hazard notes
The guarantee claim becomes invalid for damages
due to non-observance of these operating instruc-
tions! We do not assume liability for consequential
damages!
• To assure the trouble-free operation of the overflow protector you
must observe the safety instructions, warnings and the "Proper
use” which are contained in this instruction manual.
15