User Manual
LCD12864-COG
3.4 Reset Timing
Vss = 0V,Top = 25℃
Items Symbol MIN. TYP. MAX. Unit Condition
Reset time Tr - - 2.5
µS
-
Reset Low pules width Trw 2.5 - -
µS
-
Items Symbol MIN. TYP. MAX. Unit Condition
Reset time Tr - - 2.5
µS
-
Reset Low pules width Trw 2.5 - -
µS
-
Items Symbol MIN. TYP. MAX. Unit Condition
Reset time Tr - - 2.5
µS
-
Reset Low pules width Trw 2.5 - -
µS
-
Note:
*a. all timing is using 20﹪ and 80﹪ of VDD as the reference.
4. Function specifications
4.1 The Parallel Interface
Shared
6800 Mode 8080 Mode
A0 R/W E /RW H
Function
H H H L H Reads the display data
H L HÆL H L Æ H Writes the display data
L H H L H Staus read
L L HÆL H L Æ H Write Command data
Page 8 of 14