Use and Care Manual

Check Surface Burners
Push and turn a knob to the IGNITE
position.A clicking sound indicates
proper operation of the ignition
system.When lighting any burner,sparks
will appear at all burners but gas flows
from only the one selected.Once air is
purged from the supply line,burner
should light within 4 seconds.After
burner lights,rotate the knob out of the
IGNITE position.Try each burner in
succession until all burners have been
checked.
Quality of Flames
Determine the quality of flames
visually.Normal burner flames
should look like(A) or (B).
(A)Soft blue flames-
Normal for natural
gas
(B)Yellow tips on
outer cones-
Normal for propane
gas
Long,bright yellow flames are not
normal.Normal flames may show signs of
an orange tint when well heated or signs
of flickering orange due to particles in the
gas or air.

Adapting To Different Types of Gas
Before carrying out any maintenance work,disconnect the appliance from the gas and
electric supply.
To change the nozzles of burners use the following procedure:
Lift up the burners and unscrew the nozzles using an adjustable spanner of 7mm and
change the nozzles(Picture J”) with those designed for the new gas supply according to
the information shown below.
ATTENTION:After carrying out the changes described above,the technician must put
the card corresponding to the new gas supply on the appliance to take the place.this
card is found in the bag containing spare nozzles.
Burner
Type of Gas
Pressure/mbar
Nozzle Diameter
1/100mm
Auxiliary
Natural 20
20
75
Butane 30
30
45
Semi-Rapid
Natural 20
20
97
Butane 30
30
60
Rapid
Natural 20
20
115
Butane 30
30
75
Triple-ring
Natural 20
20
135
Butane 30
30
91
Recommended Pan Diameters
BURNER
PAN DIAMETERS Recommended(cm.)
Auxiliary
12-14
Semi-Rapid
14-26
Rapid
18-26
Triple-ring
22-26
Warning!!!
The timer is only used as a reminder function and does not cut off the gas. Please
close the valve in time after the bell rings