Product Literature

Dual Trajectory
The 25° setting provides
maximum distance of
throw and the 15° setting
provides improved wind
performance, radius
reduction and obstacle
avoidance.
15°
25°
OR
Specifying Information—INFINITY 35 & INFINITY 55
INFX5-XXX-XX
Body
Inlet
Arc Nozzle
Pressure
Regulation*
Activation Type Optional
INFX 5 X X X X X
3—1"
5—1
1
2"
5—Part-circle and
Full-circle
In One
INF35—30, 31, 32, 33, 34, 35, 36, 37
INF5551, 52, 53, 54, 55, 56, 57, 58, 59
6—65 psi
8—80 psi
1—100 psi
1—Standard Solenoid
2—Spike Guard™ Solenoid
3—Nickel-plated Spike Guard Solenoid
4—DC Latching Solenoid (DCLS)
6—Integrated Lynx Smart Module w/DCLS
7—Effluent
Example: When specifying an INF35 Series Sprinkler with #34 nozzle, pressure regulation at 65 psi and Spike Guard you would specify: INF35–346–2
Note:
Not all models available. * All sprinklers are equipped with the selectable pilot valve that allows settings at 50, 65, 80 and 100 psi.
INF35 CONVERSION UPGRADES
MODELS DESCRIPTION
• INF35-3134
• INF35-3537
• INF35-3134E
• INF35-3537E
INF35 w/31–34 Nozzles
(#3 Nozzle Installed)
INF35 w/35–37 Nozzles
(#5 Nozzle Installed)
INF35 w/31–34 Nozzles
(#3 Nozzle Installed), Effluent
INF35 w/35–37 Nozzles
(#5 Nozzle Installed), Effluent
INF55 CONVERSION UPGRADES
MODELS DESCRIPTION
• INF55-5154
• INF55-5558
• INF55-59
• INF55-5154E
• INF55-5558E
• INF55-59E
INF55 w/51–54 Nozzles
(#3 Nozzle Installed)
INF55 w/55–58 Nozzles
(#5 Nozzle Installed)
INF55 w/59 Nozzle
INF55 w/51–54 Nozzles
(#3 Nozzle Installed), Effluent
INF55 w/55–58 Nozzles
(#5 Nozzle Installed), Effluent
INF55 w/59 Nozzle, Effluent
Smart Access
®
Provides top accessibility to all critical components.
No digging or unsightly turf repair scars
No buried wire splices or ground faults
Pilot valve removable with water “ON”
Lower long term cost of ownership
Customizable marker
Replaceable cover if damaged
Increased labor eciency
SPECIFICATIONS
Operational
• Inlet:
- INF35: 1” ACME
- INF55: 1½” ACME
• Radius:
- INF35: 43’ – 83’
- INF55: 55’ – 92’
Flow Rate:
- INF35: 8.2 – 47.3 gpm
- INF55: 14.1 – 61.3 gpm
Precipitation Rates:
- INF35: Minimum - .41”/hr;
Maximum - .45”/hr
- INF55: Minimum - .46”/hr;
Maximum - .58/hr
Pilot Valve: Selectable at 50, 65,
80 and 100 psi
Recommended Operating
Pressure Range: 65-100 psi
(maximum – 150 psi and
minimum – 40 psi)
Activation types – Electric
Valve-in-Head:
- Standard Solenoid:
n
24 VAC, 50/60 Hz
n
Inrush: 0.30 A
n
Holding 0.20 A
- Spike Guard Solenoid:
n
24 VAC, 50/60 Hz
n
Inrush: 0.12 A
n
Holding 0.10 A
- Nickel-Plated Spike Guard
Solenoid:
n
24 VAC, 50/60 Hz
n
Inrush: 0.12 A
n
Holding 0.10 A
- DC Latching Solenoid (DCLS):
n
Momentary low voltage pulse
- Integrated Lynx Smart Module
w/DCLS:
n
Momentary low voltage pulse
Additional Features
INF35 has eight nozzle
variations (30, 31, 32, 33, 34,
35, 36 & 37)
INF55 has nine nozzle
variations (51, 52, 53, 54, 55,
56, 57, 58 & 59)
Three in-line nozzles,
rotating stream pattern
Two back nozzle positions
Stator variations: 3
Radius reduction screw 363-
4839 for fine tuning
Ratcheting riser
Nozzle base clutching
Dimensions
SMART ACCESS
®
Cover and
Compartment Diameter:
- INF35: 7
5
/8
- INF55: 7
5
/8
Body height:
- INF35: 10”
- INF55: 11
3
/8
• Weight:
- INF35: 4.26 lbs.
- INF55: 5.08 lbs.
Weight – Intergrated with
Lynx Smart Module:
- INF35: 4.95 lbs.
- INF55: 5.71 lbs.
Pop-up height to nozzle: 3¼
Warranty
Three years
Five years when installed
with Toro Swing Joints