Datasheet

HR
HanKuk Relay
R-62
HR-CR3A
Part number description
HR-CR3A
No. of poles
1: Single pole
2: Double poles
Contact arrangement
1: Form C contact
3: Form A contact
Coil voltage
DC05: 5VDC DC12: 12VDC
DC06: 6VDC DC18: 18VDC
DC09: 9VDC DC24: 24VDC
DC48: 48VDC
Contact rating
None: Standard 5A 30VDC
5A 250VAC (2 Form A, C)
10A 30VDC
10A 30VDC (1 Form A, C)
K: 16A 30VDC
16A 250VAC (1 Form A,C type only)
Enclosure
None: Sealed type, black
C: Flux free type, clear
Coil sensitivity
None: Standard (720mW)
H: High sensitive (530mW)
Part number description is provided for reference, part number cannot be arbitrarily composed. Refer to the part
numbers shown in the table below. Special designs to customer specifications are possible; please contact HR.
Part selection
󳀫
Fill in the codes to the part number by selecting them from the part number description
Part number
Nominal Coil Nominal Must operate Must release Max Nominal
voltage resistance current voltage voltage voltage power
(VDC) ( ± 10%) (mA) (VDC) (VDC) (VDC) (mW)
Sensitive coil 1 Form C, 1 Form A, 2 Form C, 2 Form A
HR-CR3A
󳀫󳀫
DC05
󳀫󳀫
5 35 144 4.0 0.5 6.5
HR-CR3A
󳀫󳀫
DC06
󳀫󳀫
6 50 120 4.8 0.6 7.8
HR-CR3A
󳀫󳀫
DC09
󳀫󳀫
9 112 80 7.2 0.9 11.7
HR-CR3A
󳀫󳀫
DC12
󳀫󳀫
12 200 60 9.6 1.2 15.6 720
HR-CR3A
󳀫󳀫
DC18
󳀫󳀫
18 450 40 14.4 1.8 23.4
HR-CR3A
󳀫󳀫
DC24
󳀫󳀫
24 800 30 19.2 2.4 31.2
HR-CR3A
󳀫󳀫
DC48
󳀫󳀫
48 3,200 15 38.4 4.8 62.4
Sensitive coil 1 Form C, 1 Form A, 2 Form C, 2 Form A
HR-CR3A
󳀫󳀫
DC05
󳀫󳀫
H 5 47 106 4.0 0.5 6.5
HR-CR3A
󳀫󳀫
DC06
󳀫󳀫
H 6 68 88 4.8 0.6 7.8
HR-CR3A
󳀫󳀫
DC09
󳀫󳀫
H 9 153 59 7.2 0.9 11.7
HR-CR3A
󳀫󳀫
DC12
󳀫󳀫
H 12 273 44 9.6 1.2 15.6 530
HR-CR3A
󳀫󳀫
DC18
󳀫󳀫
H 18 620 29 14.4 1.8 23.4
HR-CR3A
󳀫󳀫
DC24
󳀫󳀫
H 24 1,085 22.1 19.2 2.4 31.2
HR-CR3A
󳀫󳀫
DC48
󳀫󳀫
H 48 4,350 11.0 38.4 4.8 62.4
Note: All values in the chart are measured at 23ÛC
RoHS
