Datasheet
Selection Guide & Technical Data
R-61
HRHR-CR3A
Contact data
Arrangement 1 Form A (SPST) to 2 Form C (DPDT)
Contact material Ag Alloy
Initial contact resistance 100mΩ max.
Type 1 Pole typ
2 Pole type
Standard
K type
2 Form A, C
1 Form A, C
1 Form C 1 Form A
Rated load, resistive 5A 30VDC 10A 30VDC 10A 30VDC 16A 30VDC
5A 250VAC 10A 250VAC 10A 250VAC 16A 250VAC
TV-5 TV-5 TV-8
Maximum carry current 5A 10A 16A 16A
Maximum switching capacity with DC voltage: 150W 300W 300W 480W
with AC voltage: 1,250VA 2,500VA 2,500VA 3,840VA
Maximum switching voltage 250VAC
Minimum switching rating
1)
100mA 5VDC
1)
Min. Switching Load mentioned above are reference values. Therefore it is recommended to perform the confirmation test
with the actual load before production since reference values may vary according to switching frequencies, environmental
conditions and expected reliability levels.
Coil data
Nominal voltage 5VDC to 48VDC
Nominal power consumption
2)
530mW, 720mW
Operate voltage
3)
80% of nominal voltage
Release voltage
4)
10% of nominal voltage
2), 3), 4)
The values depend on coil voltage, see Part selection chart
General data
Operate time 15ms max. at nominal voltage
Release time 8ms max. at nominal voltage
Initial insulation resistance 1,000 MΩ min. (500VDC)
Dielectric strength Between open contacts: 1,000VAC
rms for 1 minute
Between contacts and coil: 5,000VACrms for 1 minute
Surge strength Between contacts and coil: 10,000V
Expected life Mechanical: More than 10,000,000 operations
Electrical: More than 100,000 operations at rated load
Vibration resistance Functional: 10 ~ 55Hz dual amplitude: 1.5mm
Destructive: 10 ~ 55Hz dual amplitude: 1.5mm
Shock resistance Functional: 10G min.
Destructive: 100G min.
Ambient temperature – 40ÛC to + 70ÛC (with no icing)
Humidity 45% to 85% RH
Weight 13g approx.
Note: The above figures are initial values
P.C. BOARD POWER RELAY
RoHS