Installation and Operation Instructions for USA only Model: HF-517U Cast Iron Freestanding Stove (EPA Approved for Washington State) Conform to UL 1482 - 2010 Report # 375-S-01-2 KINDLY SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
Safety Notice If this solid fuel room heater is not properly installed, a house fire may result. For your safety and to reduce the risk of fire, follow the installation instructions. Contact local building officials, fire officials or the authority having jurisdiction about restrictions and installation inspection requirements in your area, including the need to obtain a permit. Kindly save these instructions for future reference.
Introduction Congratulations on purchasing a genuine Hi Flame® stove. When cared for properly, the high quality, finely crafted cast iron stoves and fireplace inserts will offer many years of reliable performance. This instruction manual has been developed to ensure optimum performance from the Hi Flame® stove. It's very important that you thoroughly read and understand all instructions before using your new stove or fireplace insert. Table of Contents Page VERY IMPORTANT .................................
Sample of Label 3
Stove Safety When properly maintained and operated your stove should give you many years of service. However, there are important safety aspects of these products that you need to be aware of when operating a wood stove. 1. Hi Flame recommends that you have your new stove installed by a professional installer of solid fuel burning appliances. 2. If this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions.
Check Building Codes • • • • When installing, operating and maintaining your stove, follow the guidelines presented in these instructions, and make them available to anyone using or servicing the stove. Your city, town, county or province may require a building permit to install a solid fuel burning appliance. In the U.S.
The floor protection If the stove is to be installed on a combustible floor, it must be placed on a non-combustible hearth pad. In the USA, the floor protector must extend 8” beyond each side of the fuel loading door and 16” to the front (18” to the front in Canada). (See fig. 4) Floor protection under the stove must be a UL 1618 Type 1 Ember Protector composed of noncombustible material for protection from radiant heat, sparks and embers.
Installation Clearances It is extremely important that you respect required installation distances and that you respect local installation regulations. This is for your safety. The manufacturer is not responsible for the product if it is not installed following these recommendations. These clearances may only be reduced by means approved by the regulatory authority.
Well sealed flue system Only materials and items approved for solid fuel stoves should be used for your stove. Under no circumstances should you use aluminum or galvanized steel pipes for your stove flue. Always fit pipes with the narrow side down. This will allow any creosote to run down the inside of the pipe and not to come out and cause an unsightly mess and possible fire hazard. All joints in the flue system should be sealed with fire cement and/or an appropriate fire resistant rope or gasket.
This prevents any amount of condensed or liquid creosote from running down the outside of the pipe or the stovetop. All joints, including the flue collar connection, must be secured with three sheet metal screws to ensure that the sections do not separate. For the best performance, the chimney connector should be as short and direct as possible, with no more than two 90° elbows. The maximum horizontal run is 36" (914mm) and a recommended total length of stovepipe should not exceed 10 feet (3 m).
Factory-Built Chimney When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass-through and "T" section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer.
Masonry Chimney Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed.
Masonry Fireplace There are listed kits available to connect a stove to a masonry fireplace. The kit is an adapter that is installed at the location of the fireplace damper. The existing damper may have to be removed to allow installation.
Combustible Wall Chimney Connector Pass-Throughs 13
Operating Your Stove • Do not use a grate, andiron or other fuel support method. Build fire directly on the hearth. • Only open door to fuel/refuel the stove. Excess air can cause the stove to over fire. Do not over fire. If chimney or stove is glowing red, you are over firing. • Do not build the fire too close to the glass. Do not abuse the glass doors. Do not strike or slam the door shut.
cause the stove to burn slower. This may cause some blackening of the stove glass, but this should burn off once the stove is burning brightly again. Refueling Before refueling your stove, turn the air supply on high for a few moments until there is a good fire within the stove. This will ensure there is no build-up of harmful gases in the stove when the door is opened and will also get the new fuel burning quickly and not allow it to kill the fire.
Stove Maintenance Check stove regularly Creosote: Formation and Need for Removal When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. If a significant layer of creosote has accumulated (3 mm or more), it should be removed to reduce the risk of a chimney fire.
Care of glass At times, especially when the air control is turned to a low setting or when damp wood is used, the stove glass will blacken. This is caused by fuel that is not completely burned, but the buildup on the inside of the glass will normally burn off when a good hot fire is established in the stove. There may be times, however, when you need to clean the glass. To do this, use a soft cloth and a non-abrasive glass cleaner. Only ever clean the glass when the stove is cold.
HF-517U Parts List 18
HF-517U Parts List 1. Hob 20. Ash shovel 2. Inner Top 21. Operating tool 3. Bearing plate for secondary air deflecting plate 22. Legs (4) 4. Secondary air deflecting plate (tiered) 23. Base 5. Air wash deflecting plate 24. Grate frame 6. Front 25. Right, side fire brick 7. Side panel – Left & Right 26. Left, side fire brick 8. Front air flow channel 27. Back side fire brick 9. Fire fence 28. Air wash slider 10. Air wash control lever 29. Air wash slider holding plate 11. Glass 30.
Trouble Shooting Fire not burning A stove not burning is generally caused by either a shortage of air and/or incorrect or damp fuel. If fuel is not the problem check: • • • • That the air controls are opened. That there is no blockage in the flue system. That the open end of the flue is above the height of any nearby obstructions. That there is a sufficient air supply into the room and that this supply is not being taken by an extractor fan.
Chimney fire Chimney fires occur when soot and creosote that have built up in the flue system ignite. If the stove is operated properly and the flue checked and cleaned regularly, then chimney fires should not occur. These fires can be very dangerous and must be avoided. Try to maintain good, hot fires in the stove whenever possible and at least once during every firing, open the air controls and allow the stove to burn on full for a short while until the entire fire bed is glowing red.
Hi Flame America, Inc. Warranty Warranty Policy & Procedures If you believe your Hi Flame® stove is defective, you should contact your nearest authorized Hi Flame America stove dealer, who will process a warranty claim. In order to qualify for warranty coverage, Hi Flame America must receive notice of a possible defect within thirty (30) days of being discovered, or reasonably could have been discovered.
Exclusions and Limitations NOTICE: This warranty is void if installation or service is performed by someone other than an authorized installer or service agency, or if installation is not in conformance with the installation and operating instructions contained in this owner's manual or local and/or national fire and building regulations. A listing of local authorized installers and service agencies can be obtained from the National Fireplace Institute at http://www.nficertified.org.