SDS
IDH number: 1552177 Product name: LOCTITE® 3370™ POLYURETHANE ADHESIVE/SEALANT
Page 4 of 6
10. STABILITY AND REACTIVITY
Stability:
Stable
Hazardous reactions:
Will not occur.
Hazardous decomposition products:
Oxides of carbon. Oxides of nitrogen.
Incompatible materials:
Alcohols. Amines. Acids and bases. Reacts with water.
Conditions to avoid:
Keep away from heat, ignition sources and incompatible materials.
11. TOXICOLOGICAL INFORMATION
Hazardous components NTP Carcinogen IARC Carcinogen
OSHA Carcinogen
(Specifically Regulated)
Polyvinyl chloride No No Yes
Xylenes No No No
Titanium dioxide No Group 2B No
Distillates (petroleum), hydrotreated light No No No
Calcium dihydroxide No No No
Calcium oxide No No No
Methylenebis(phenylisocyanate) No No No
Ethylbenzene No Group 2B No
Hazardous components Health Effects/Target Organs
Polyvinyl chloride Respiratory
Xylenes Cardiac, Central nervous system, Irritant, Kidney, Liver
Titanium dioxide Irritant, Respiratory, Some evidence of carcinogenicity
Distillates (petroleum), hydrotreated light Irritant, Lung
Calcium dihydroxide Irritant, Corrosive
Calcium oxide Irritant, Corrosive, Eyes
Methylenebis(phenylisocyanate) Irritant, Respiratory, Allergen
Ethylbenzene Irritant, Central nervous system
12. ECOLOGICAL INFORMATION
Ecological information:
No specific studies have been conducted by Henkel on the ecotoxicity or
environmental fate of this material; however, commonly available data on the
material indicate that uncontrolled releases to soil, ground water, or surface
waters could entail acute and/or chronic ecological effects, depending on the
quantity and concentration of such releases. Releases of volatile components
to the atmosphere are not believed to entail significant ecological
consequences provided such releases are within the exposure levels set forth
in this document. Accordingly, all appropriate measures should be taken to
avoid uncontrolled releases to the environment, and any spills or other
uncontrolled releases which may occur should be contained and cleaned up
immediately in accordance with Section 6.