Third Party Verification Claim

Page 99 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
Only one side of the primary circuit connected to
the test equipment when the primary switch is in
the on position or when a primary switch is not
used
N/A
69
Grounding Continuity Test
N/A
69.1
Continuity of grounding connection
N/A
69.1.1
Each cord-connected appliance having provision
for grounding shall be tested, as a routine
production-line test, to determine that grounding
continuity exists between the grounding blade of
the attachment plug and the accessible dead-
metal parts of the appliance that are likely to
becomeenergized
N/A
69.1.2
Only a single test is required to be conducted if the
accessible metal selected is conductively
connected by design to all other accessible metal
N/A
69.2
Electrical indicating devic
N/A
69.2.1
Any effective indicating device (an ohmmeter, a
battery and buzzer combination, or the like) may
be used to determine compliance with the
requirements specified in 69.1.1 and 69.1.2
N/A
70
Hair Dryer Power Input Test
N/A
70.1
The power input to each hand-supported hair dryer
shall be tested as described in 70.2, as a routine
production-line test
N/A
70.2
The power input is to be measured with the dryer
at operating temperature under full-load conditions
while connected to a circuit maintained at
N/A
120 6 volts for a dryer rated 110 120 volts
N/A
240 12 volts for a dryer rated 220 240 volts, or
N/A
The marked voltage on the dryer for all other
voltage ratings
N/A
Control switches or the equivalent, if provided, are
to be set to result in the maximum power input
N/A
70.3
The results are acceptable if the power input to a
dryer is within the inclusive range of 90 110
percent of the rating.
N/A
70.4
With regard to 70.3, the wattage of a dryer that
has its electrical rating marked only in amperes
and volts will be assumed to be the product of
those two values
N/A
71
Details
P