Third Party Verification Claim

Page 98 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
68.6
When the appliance uses a solid-state component
that is not relied upon to reduce the risk of electric
shock and that can be damaged by the dielectric
potential, the test described in
68.1 may be conducted before the component is
electrically connected, only when a random
sampling of daily production is tested at the
potential specified in Table 68.1. The circuitry may
be rearranged for the purpose of the test to
reduce the likelihood of solid-state component
damage while retaining representative dielectric
stress of the circuit.
N/A
68.7
The test equipment shall include
N/A
A transformer having an essentially sinusoidal
output,
N/A
A means of indicating the test potential
N/A
68.8
If the output of the test equipment transformer is
less than 500 volt-amperes, the equipment shall
include a voltmeter in the output circuit to directly
indicate the test potential
N/A
68.9
If the output of the test equipment transformer is
500 volt-amperes or larger, the test potential shall
be indicated by:
N/A
A voltmeter in the primary circuit or in a tertiary
winding circuit,
N/A
A selector switch marked to indicate the test
potential, or
N/A
In the case of equipment having a single test
potential output, a marking in a visible location to
indicate the test potential. When a marking is used
without an indicating voltmeter, the equipment
shall include a positive means, such as an
indicator lamp, to indicate that the manual reset
switch has been reset following a dielectric
breakdown
N/A
68.10
Test equipment other than that described in
68.7 68.9 may be used if the intended factory
test is accomplished
N/A
68.11
During the test described in 68.1, the primary
switch is to be in the on position, both sides of the
primary circuit of the appliance are to be
connected together and to one terminal of the test
equipment, and the second test equipment
terminal is to be connected to the accessible dead
metal
N/A
Exception No. 1: An appliance (resistive, high-
impedance winding, and the like) having circuitry
not subject to excessive secondary voltage buildup
in case of dielectric breakdown during the test may
be tested with
N/A
A single-pole primary switch, if used in the off
position, or
N/A