Third Party Verification Claim

Page 94 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
65.8
To determine compliance with 13.3.1.16, an
appliance shall be placed on a supporting surface
inclined at 10 degrees from the horizontal and is to
be oriented to the position most likely to cause
tipping. Any adjustable or movable part that will
affect the location of the center of gravity of the
appliance shall be placed in the position most
likely to contribute to tipping. Blocks shall be used
to prevent the appliance from sliding down the
incline.
N/A
65.9
After completion of the test of 65.8 and with the
base of the appliance still at a 10 degree angle,
the hand-supported part of the appliance shall be
removed and inserted ten complete times.
N/A
65.10
A sample of the appliance provided with the
locking mechanism required by 13.3.1.17 shall be
subjected to the unenergized mechanical testing
detailed in 65.11 without occurrence of any of
the following
N/A
Producing a condition that affects the mechanical
performance of the appliance
N/A
Producing a condition that prevents the appliance
plug from being securely held and locked in place
during normal operation; or
N/A
65.11
The locking mechanism shall be subjected to
10,000 cycles of assembly/disassembly at a rate
not to exceed 10 cycles per minute. At the
conclusion of the test, the locking mechanism shall
be examined for compliance with 65.10
N/A
66
Thermoplastic Motor Insulation Systems
N/A
66.1
General
N/A
66.1.1
Motors that employ thermoplastic materials to
electrically isolate the windings and similar live
parts from other live parts or noncurrent- carrying
metal parts are to be subjected to the tests
specified in 66.2 and 66.3
N/A
Exception No. 1: A motor that functions to move
air only with a direct mounted fan need not be
subjected to the test in 66.3.
N/A
66.2
Abnormal conditioning
N/A
66.2.1
The motor is to be subjected to the abnormal
conditioning described in 66.2.2 and shall comply
with all of the following conditions
N/A
The 3 ampere fuse shall remain intact and
N/A
The material under test shall withstand without
breakdown, the dielectric voltage-withstand
potential specified in Dielectric Voltage Withstand
Test, Section 45 immediately following
the conditioning specified in 66.2.2 and with
the 3 ampere fuse removed from the
circuit.
N/A