Third Party Verification Claim
Page 93 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
Each sample is to be dropped three times so that,
in each drop, the sample strikes the surface in a
position different from those in the other two drops.
Three samples shall be employed for the test;
however, if the manufacturer elects, fewer
samples may be used in accordance with Figure
65.1. The overall performance is acceptable upon
completion of any one of the procedures
represented in that Figure. If any sample does not
comply on its first series of three drops, the results
of the test are unacceptable
N/A
65.4
A sample of the appliance constructed as detailed
in 13.3.1.14 shall be subjected to the testing
detailed in 65.5 without occurrence of any of the
following
N/A
Making uninsulated live parts accessible to
contact;
N/A
Producing a condition that affects the mechanical
performance of the appliance
N/A
65.5
A sample of the appliance shall be connected to
a supply adjusted to rated voltage and operated
under conditions of maximum loading. The
appliance coupler shall be inserted and
withdrawn for 50 cycles of operation at a rate of
not more than 10 operations per minute with the
blades or pins of the mating part connected for not
more than one second. At the conclusion of the
test, the appliance shall be examined for
compliance with 65.4
N/A
65.6
A sample of the appliance constructed as detailed
in 13.3.1.15 shall be subjected to the testing
detailed in 65.7 without occurrence of any of the
following
N/A
Making uninsulated live parts accessible to contact
N/A
Producing a condition that affects the mechanical
performance of the appliance;
N/A
65.7
A sample of the appliance shall be connected to a
supply adjusted to rated voltage and operated
under conditions of maximum loading. The hand
supported portion of the appliance shall be
inserted and withdrawn from the mating connector
for 10,000 cycles of operation at a rate not more
than 10 operations per minute with the blades or
pins of the mating part connected for not more
than one second. At the conclusion of the test,
the appliance shall be examined for compliance
with 65.6
N/A