Third Party Verification Claim

Page 91 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
63.2
For each of the types of conditioning specified in
63.3 63.7, three samples of a label are to be
applied to the same test surface used in the
intended application. The labels are to be applied
to the test surface no less than 24 hours prior to
testing.
P
63.3
Three samples of the labels are to be investigated
as received.
P
63.4
Investigation of samples at the end of each test as
indicated in 63.5 63.7 is to be made
P
Immediately following removal from each test
medium and
P
After exposure to room temperature for 24 hours
following removal from each test medium
P
63.5
Three samples of the labels under test are to be
placed in a full-draft circulating-air oven
maintained at the temperature indicated in Table
63.1 for 240 hours
P
63.6
Three samples of the labels under test are to be
immersed in water at a temperature of 23.0
2.0°C (73.4 3.6°F) for 48 hours
P
Exception: In place of the immersion test, labels
intended for use on clean, dry equipment may be
suspended for 72 hours in a humidity cabinet at
32 2°C (89.6 3.6°F) with an 85 5 percent
relative humidity
N/A
63.7
If the labels are exposed to unusual conditions in
service, such as exposure to medicant,
detergents, oil, or other substances, three
additional samples are to be conditioned as
follows. The samples are to be immersed in a
solution representative of service use, maintained
at 23.0 2.0°C (73.4 3.6°F) for 48 hours. For
exposure to detergents, the solution is to consist of
a mixture of 25 grams of a commercial detergent
per liter of water
N/A
64
Flammability Test Wax for Depilatory Appliances
N/A
64.1
The wax for a depilatory appliance shall comply
with the flammability test described in 64.2
N/A
Exception: This requirement does not apply to
constructions in which the molten wax is stored in
aclosed applicator and is not exposed to external
sources of ignition before being dispensed
N/A
64.2
The depilatory appliance is to be loaded with the
maximum recommended amount of wax and
operated at the voltage specified in
44.1.13 and the highest heat setting until the
molten wax is at its maximum temperature. A
wooden match is then to be lighted and touched
against the surface of the wax. The wax in the
reservoir shall not ignite
N/A