Third Party Verification Claim
Page 88 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
60.2
Each sample is to be operated continuously for
1,000 hours. The test voltage (as specified in
44.1.13) is to be increased, if necessary, to cause
the wattage input to the appliance to be equal to
its marked wattage rating. Each sample is to be
placed on a thermal insulating surface, supported
by its stand, if provided. Adjustable temperature
controls are to be adjusted for maximum heating.
Each sample of an appliance having an
automatically controlled preheat cycle is to be
subjected to 6,000 cycles of operation.
Each cycle is to consist of energizing the
appliance from room temperature to the maximum
stabilized temperature condition, then de-
energizing and cooling to room temperature.
Forced cooling, such as by directing air jets at the
appliance, may be used to reduce the cooling
time. The on time of
each cycle is to be such that the total
on time will be no less than 1,000 hours.
Following the successful completion of the 6,000
cycles of operation or the 1,000-hour continuous
operation, and after being allowed to cool to room
temperature, each sample is to be tested for
compliance with the Leakage Current Test,
Section 38
N/A
Exception: The appliance is not required to be
subjected to the 6,000 cycles of operation if aged
for 1,000 hours at a temperature equal to the
maximum temperature during the preheat cycle.
N/A
60.3
Each sample, while at room temperature, is then
to be subjected to impacts as described in 60.4
–60.6. After each drop for a hand-supported
appliance and the one impact for other types of
appliances, the leakage current test is to be
repeated. After the leakage current test, each
sample is to be subjected to the Dielectric Voltage-
Withstand Test, Section 45. For a hand-supported
appliance, the dielectric voltage-withstand test is to
be conducted after the final leakage current test
N/A
60.4
Each of three samples of a hand-supported
portable appliance is to be dropped 3 feet (0.91
m) to strike a hardwood surface in the position
most likely to produce adverse results. The
hardwood surface is to be as described in 34.5.
Each sample is to be dropped three times so that,
in each drop, the sample strikes the surface in a
position different from those in the other two drops
N/A
60.5
Stationary, fixed, counter-supported, or floor-
supported appliances are to be subjected to the
ball impact test described in 60.6
N/A