57
Grounding Continuity Test
N/A
57.1
The resistance of the grounding path between a
dead-metal part of an appliance as specified in
27.3 and the equipment grounding terminal or lead
or the point of attachment of the wiring system or
the grounding blade of an attachment plug shall be
no more than 0.1 ohm
N/A
57.2
With reference to 57.1, the resistance may be
determined by any convenient method. If the
results do not comply with the requirement
specified in 57.1, either a direct- or alternating-
current at a potential of no more than 12 volts, and
equal to the current rating of the maximum-
current-rated branch circuit overcurrent protective
device that may be used with the appliance, is to
be passed from a dead- metal part to either the
N/A
Equipment grounding terminal
N/A
Point of attachment of the wiring system, or
N/A
The resulting drop in potential is to be measured
between these two points. The resistance in ohms
is to be determined by dividing the drop in
potential in volts by the current in amperes passing
between the two points
N/A
58
Test for Permanence of Cord Tag for Hand-Supported Hair-Drying Appliances
N/A
58.1
General
N/A
58.1.1
To determine compliance with 72.4.2 and 72.4.4,
representative samples that have been subjected
to the tests described in 58.2.2
58.3.1 shall meet the following requirements
N/A
The tag shall resist tearing for longer than 1/16
inch (1.6 mm) at any point
N/A
The tag shall not separate from the power supply
cord
N/A
58.2
Test conditions
N/A
58.2.1
For each type of conditioning specified in 58.2.2
58.2.4, three samples of the tag applied to the
power supply cord in the intended manner are to
be used. If tags are applied by an adhesive, tests
are to be conducted no sooner than 24 hours after
application of the tag
N/A
58.2.2
Three samples are to be tested as received
N/A
58.2.3
Three samples are to be tested at the end of 30
minutes of conditioning at a room temperature of
23 2°C (73.4 3.6°F) and 50 5 percent relative
humidity, following conditioning in an air-
circulating oven at 60 1°C (140 1.8°F) for
240 hours.
N/A
58.2.4
Three samples are to be tested within 1 minute
after exposure for 72 hours to a humidity of 85
5 percent at 32 2°C (89.6 3.6°F).
N/A
58.3
Test method
N/A