Third Party Verification Claim
Page 81 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
50.2
To conduct this test, the specified units of the ALCI
are to be assembled to the test fixture shown in
Figure 50.1 so there is no interference with the test
procedure. Each unit is to be mounted with the
point of cord entry into the ALCI at the center of
rotation. For the start of the test, the cord is to
hang vertically downward. The cord is to be
passed through the two cord guides spaced 3/4
inch (19.1 mm) apart and located 9 inches (229
mm) below the cord entry into the ALCI. The
cord guides are to have smoothly rounded edges
where they may be contacted by the cord. A 1/4-
pound (113- gram) unsupported weight is to be
attached to the free end of the cord, 12 inches
(305 mm) from the cord entry into the ALCI. The
conductors of each unit are to be connected in
series with each other, and with a low-voltage,
low-current relay circuit that will shut down the
flexing machine if a conductor opens
P
50.3
Six units are to be subjected to 6,000 cycles of
flexing at a rate of 10 cycles per minute in the
plane of the face of the ALCI. The test is to be
repeated using six additional units with the flexing
in the direction perpendicular to the plane of the
face of the ALCI
N/A
50.4
With reference to 50.3, each cycle consists of a
90-degree rotation of the unit in one direction; a
180-degree rotation in the opposite direction; and
then a return to the starting point
N/A
51
Test for Security of Swivel Assembly
N/A
51.1
The supply swivel assembly on one as-received
sample and three conditioned samples (as
described in 51.2) are each to be subjected to a
direct pull force of 35 pounds (156 N) for 1 minute
with the force applied at any angle the construction
of the appliance will permit. The appliance is to be
energized at rated wattage during this test. The
result is acceptable if
N/A
There is no displacement of the cord and no
evidence of intermittent contact in the electrical
circuit and
N/A
The appliance complies with 8.5.3 during and after
the test.
N/A
Exception: The direct pull force for an appliance
weighing 1/2 pound (227 g) or less (exclusive of
the cord) is to be 20 pounds (89 N).
N/A
51.2
With regard to 51.1, the conditioned samples are
to be maintained for 7 hours at a temperature of
10°C (18°F) higher than the temperature
measured on the swivel assembly during the
normal temperature test, but not less than 70°C
(158°F)
N/A
52
Swivel Endurance Test
N/A