Third Party Verification Claim
Page 8 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
8.5.11
The requirement in 8.5.9 will also necessitate that
a switch, relay, solenoid, or the similar part be
individually and completely enclosed unless there
is no opening in the bottom of the appliance
enclosure, or it can be shown that malfunction of
the component would not result in a risk of fire
N/A
Exception: Terminals of a switch, relay, solenoid,
or the like are not required to be individually and
completely enclosed
N/A
8.5.12
The barrier specified in 8.5.10 shall be horizontal,
shall be located as indicated in Figure 8.3, and
shall have an area no less than that described in
Figure 8.3. An opening such as for drainage
or ventilation, is permitted in the barrier if such
an opening would not permit molten metal, burning
insulation, or flaming particles to fall on
combustible material
N/A
8.6
Doors and covers
N/A
8.6.1
The door or cover of an enclosure shall be
provided with means for holding it in the closed
position
N/A
8.6.2
The door or cover of an enclosure shall be
hinged (or similarly attached) if it gives access to
any overload protective device, the functioning of
which requires renewal, or if it is necessary to
open the cover in connection with the operation
of the protective device. Such a door or cover shall
be provided with a latch or similar device and shall
be tight-fitting or shall overlap the surface of the
enclosure around the opening
N/A
9
Reduction of Risk of Injury to Persons
P
9.1
General
P
9.1.1
Materials that are relied upon to reduce the risk of
injury to persons shall have such properties as to
meet the demand of intended loading conditions
P
9.1.2
Asbestos shall not be used
N/A
9.1.3
A moving part that can result in a risk of injury to
persons shall be enclosed or provided with other
means to reduce unintentional contact.
N/A
9.1.4
With respect to the requirement specified in 9.1.3,
the construction and intended use of the appliance
are to be considered in investigating a guard or
enclosure. Among the factors to be evaluated in
evaluating the acceptability of an exposed moving
part are
N/A
The degree of exposure;
N/A
The sharpness of the moving part; and
N/A
The possibility of fingers, arms, hair, or clothing
being drawn into the moving part (such as at
points where gears mesh, where belts travel onto
a pulley, or where moving parts close in a pinching
or shearing action)
N/A