Third Party Verification Claim
Page 78 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
47.1
An appliance that may alternately be used wet and
dry (such as a hair dryer-styler having comb and
brush accessories that may be used for setting or
styling of wet or damp hair and then used as a
dryer, or a hair untangler) shall be tested as
described in 47.2 – 47.6
P
47.2
One sample is to be subjected to this test in an
unenergized condition. Any attachment is to be
oriented to result in the most unfavorable condition
of use
P
47.3
Each sample is to be oriented above a standard
test solution (consisting of 1/2 gram of calcium
sulfate per liter of water) so that the comb teeth or
the center row (or rows) of brush bristles are
pointing vertically downward. While held in this
position, and without axial rotation, jerking or
shaking, the sample is to be lowered so that the
teeth or bristles enter the test solution. The depth
of insertion is to be such that the exposed bases
of the teeth or bristles are at the surface of the
water. The sample is to be held in this position for
2 seconds, then removed from the water without
changing the angle of the appliance and then tilted
to a vertical position with the accessory end up.
This position is to be held for 5 seconds, after
which the original position is to be resumed and
the sample again dipped into the water as before.
This operation is to be repeated without
interruption a total of ten times at the nominal rate
of six per minute
P
47.4
Following the dipping cycles, and while being held
in its final vertical position, the sample is to be
completely and closely wrapped in metal foil. The
foil is to contact all exposed accessible dead-metal
parts, if any. The sample is then to be oriented in
the most unfavorable position with regard to
components (such as switches, and the like) and
subjected to the dielectric voltage-withstand test
described in 47.5
N/A
47.5
The results are acceptable if the appliance, in an
unenergized condition, withstands for 1 minute
without breakdown a 60-hertz essentially
sinusoidal potential of 2,500 volts applied between
live partsand the foil wrapping
N/A
47.6
If the appliance is supplied with one or more
accessory attachments, the complete moisture test
is to be conducted using each accessory. Samples
of the appliance are to be in operating condition
for this test
N/A
48
Strain Relief Test
P
48.1
The strain relief means provided on an attached
flexible cord, when tested in accordance with 48.2,
shall withstand for 1 minute a pull of 35 pounds
force (156 N) applied to the cord