Page 76 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
46.9.5
An abnormal test is also to be conducted by
operating the appliance under the conditions of
intended use, as described in 44.2.1 and 44.2.2,
but defeating the temperature control that operates
to keep the wax temperature at or below 75°C
(167°F). The visible overheat condition indicator
specified in 9.3.5 shall function when the wax
temperature exceeds 75°C.
N/A
46.10
Hair dryer immersion protective devices with
convenience receptacles
N/A
46.10.1
To determine compliance with 7.9(h), the hair
dryer immersion protective device shall not
present a risk of fire or electric shock when tested
as described in 46.10.2 – 46.10.5.
Additionally, if the immersion protective device is
functional at the end of the test, it shall comply
with the applicable requirement in the high-
resistance ground faults test specified in the
Standard for Ground-Fault Circuit-Interrupters, UL
943
N/A
46.10.2
With regard to the requirement specified in
46.10.1, a risk of fire or electric shock is
considered to exist if any of the following occur
N/A
Glowing, charring, or flaming of the cheesecloth as
specified in 46.10.3
N/A
Opening of the 3-ampere fuse as specified in
46.10.3
N/A
46.10.3
The immersion protective device is to be plugged
into a duplex receptacle. The outlet’s face of the
duplex receptacle is to be in a vertical plane. The
test voltage and frequency are to be in accordance
with 44.1.13. The supply circuit is to be protected
by a 20-ampere nontime-delay fuse. During the
test, the device is to be draped with a double layer
of cheesecloth conforming to the outline of the
device. Exposed dead-metal parts of the device
are to be connected to earth ground through a 3-
ampere nontime-delay fuse. A user-serviceable
fuse is to be effectively defeated. The hair dryer is
to be operated with its temperature and speed
control adjustments set in the positions that will
result in the most severe test. The convenience
receptacle is to be connected to a resistive load
adjusted to 15 amperes. Operation is to be
continued for 7 hours or until one or more of the
following results are observed:
N/A
A risk of fire or electric shock develops (see
46.10.2)
N/A
The branch-circuit fuse opens
N/A
If the results in (b), (c), or (d) occur, additional
tests as indicated in 46.10.4 shall be conducted
N/A