Third Party Verification Claim

Page 75 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
46.9.1
If a wax depilatory appliance uses one or more
automatic reset temperature controls, all such
controls are to be short-circuited and the appliance
is to be operated under the conditions described
in46.9.2 and 46.9.3
N/A
Exception: Acceptable limit controls tested for
100,000 cycles of operation are not to be
short-circuited
N/A
46.9.2
The appliance is to be operated empty and also
with the maximum recommended amount of wax.
A movable part or cover is to be in the intended
position resulting in the most adverse conditions. A
self-closing cover (as described in 9.3.4) is to
remain in its closed position
N/A
46.9.3
One sample is to be tested under each condition in
46.9.2. Each sample is to be placed on a white,
tissue-paper-covered soft pine wood surface in a
draft-free location. The sample is to be draped with
a double layer of cheesecloth and connected to a
circuit of the voltage as specified in 44.1.13.
Adjustable temperature controls are to be set for
maximum heating.
Exposed dead-metal parts of the appliance are to
be connected to ground through a 3-ampere,
nontime-delay plug fuse. Operation is to be
continued in this manner for 7-1/2 hours, or until a
manual reset limit control or thermal cutoff opens
the circuit. If a limit control can be manually reset
without disassembling the appliance, the control is
to be held in the on position until 7-1/2 hours of
operation elapse or the ultimate results are
obtained. If a manually- reset limit control cannot
automatically reset when the reset means is held
in the
on position, the control is to be reset as
quickly as possible after each tripping for a total of
four times or for the number of cycles for which it
can be reset during the 7-1/2-hour period,
whichever is less. The maximum temperature of
the wax, as specified in 44.2.3, shall be recorded
during wax heating. The maximum temperatures
of the interior surface(s) of the wax reservoir(s)
shall be recorded during wax heating and empty
operation
N/A
46.9.4
The results are acceptable if
N/A
There is no glowing of the supporting surface,
flaming of the cheesecloth, or similar manifestation
of a risk of fire
N/A
There is no degradation of the enclosure material
exposing uninsulated current-carrying parts to
contact;
N/A
The fuse in the grounding connection does not
rupture; and
N/A