Third Party Verification Claim
Page 72 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
46.5.2
The appliance shall have its voltage selector set in
any marked supply-circuit voltage position with the
equipment connected to any one of the rated
supply circuits. The combination of selector
settings and supply circuit to which the equipment
is connected is to be that which develops the most
severe operating conditions
N/A
46.5.3
If provided, an externally operable input voltage
selector is to be operated for 25 cycles with the
appliance operating at the minimum rated voltage
and for 25 cycles with the appliance at the
maximum rated voltage. Each cycle is to consist of
moving the voltage selector to its alternate position
and back at a rate of 6 cycles per minute, with the
voltage selector in each position for 5 seconds.
The operating and temperature controls are to be
set so as to result in the most adverse operating
conditions
N/A
Exception: If an externally operable voltage
selector switch interlocks with the power switch
and cannot be operated with the power switch in
the on position, the test procedure will be as
described in 46.5.4.
N/A
46.5.4
For an externally operable voltage selector switch
that interlocks with the power switch and cannot
be operated with the power switch in the on
position, the voltage selector is to be operated for
25 cycles each at the maximum and the minimum
rated voltages. Each cycle is to consist of the
following steps
N/A
With the power switch in the off position, move the
voltage selector to the alternate position;
N/A
Turn the power switch on and operate the
appliance for 5 seconds
N/A
46.6
All appliances – short-circuit, stall tests
P
46.6.1
A motor in a limited-energy circuit is to be short-
circuited and, as a separate test, is to be stalled. A
motor in a low-voltage circuit is to be stalled. Any
solid-state device, such as a rectifier, a transistor,
a resistor, or a capacitor, is to be subjected to the
tests described in 46.6.2 and 46.6.3
N/A
Exception: The tests referenced in 46.6.1 are not
required on a motor in a limited-energy circuit or
low-voltage circuit when the motor’s insulation
system and spacings are provided as applicable
for the line voltage involved
N/A