Third Party Verification Claim

Page 71 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
46.4..6.8
The samples shall be mounted in the orientation,
provided with the attachment(s), and operated at
the heater settings that cause the highest
temperatures on polymeric materials near the
heater elements
N/A
46.4.6.9
The samples shall be operated for 30 minutes to
obtain stabilized temperatures. A sample whose
temperature control operates during that time
frame shall have its input voltage incrementally
reduced, to lower the wattage drawn by 10
percent, until the sample is able to operate without
disruption
N/A
46.4.6.10
The voltage to the internal motor shall then be
reduced as follows, recording the motor speed at
each step
N/A
At a rate of 1 volt per minute for a motor operating
at 30 volts or less or
N/A
At a rate of 5 volts per minute for all other motors.
N/A
46.4.6.11
The motor voltage and speed at the point when
a temperature control operates to open all heater
and motor circuits shall be recorded. If all heater
and motor circuits are not interrupted by operation
of a temperature control, then the motor speed is
to be reduced until the limit control operates or to a
stopped condition
N/A
46..4.6.12
A sample for which a (non-resettable) limit control
operates before a temperature control shall be
replaced by an alternate sample. The alternate
sample shall be subject to 46.4.6.13 based on the
data recorded on the nonfunctional original sample
N/A
46.4.6.13
The appliance shall then be operated under the
conditions of 46.4.6.8 with the internal motor
operated under either conditions (a) or (b)
below
N/A
The motor input voltage set at the voltage
recorded under 46.4.6.11 plus 10 percent of the
difference between that voltage and the original
voltage measured under 46.4.6.2 or
N/A
The motor speed adjusted to the speed recorded
under 46.4.6.11 plus 10 percent of the difference
between that speed and the original speed
measured under 46.4.6.2
N/A
46.5
Dual-voltage appliances
N/A
46.5.1
In addition to the applicable tests described in
46.2.1 46.4.5.1, a dual-voltage appliance shall
be subjected to the tests described in 46.5.2
46.5.4. These tests are subject to the test
conditions described in 46.1.2 and the acceptance
criteria described in 46.1.1. There shall be no
electrical or mechanical breakdown of the voltage
selector switch.
N/A