Third Party Verification Claim

Page 7 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
8.5.2
A part of the outer enclosure that is capable of
being opened or removed by the user without
using a tool (to attach an accessory, to make an
operating adjustment, to replace a fuse, or for
other reasons) is to be opened or removed when
determining compliance with 8.5.1.
N/A
8.5.3
The enclosure of an appliance shall have no
opening that permits a probe, as illustrated in
Figure 8.1, to touch any part that involves a risk of
electric shock
P
8.5.4
With regard to 8.5.3, the probe is to be articulated
into any configuration and rotated or angled to any
position before, during, or after insertion into the
opening. The penetration shall be to any depth
allowed by the opening size, including minimal
depth combined with maximum articulation. The
probe shall be applied with the minimum force
required to determine accessibility and not as an
instrument to evaluate the strength of a material
P
8.5.5
An opening that will permit entrance of a 1-inch
(25.4-mm) diameter rod is permitted when it
complies with the conditions shown in Figure 8.2.
No such parts
N/A
8.5.6
A live part of a limited-energy circuit in 5.30
requires the same degree of protection against
unintentional contact as a live part of a line voltage
circuit
N/A
8.5.7
Insulated brush caps do not require additional
enclosure
P
8.5.8
An area of an enclosure that is provided with a
group of openings or with a guarded opening
(such as a grille, louver, or screen) is to be
subjected to the strength of enclosure test
described in 35.1
N/A
8.5.9
The enclosure of a remotely or automatically
controlled appliance shall reduce the risk of molten
metal, burning insulation, or flaming particles, from
falling on combustible materials, including the
surface upon which the appliance is supported
N/A
8.5.10
The requirement in 8.5.9 will necessitate the use
of a barrier of material that is resistant to
combustion
N/A
Under a motor unless
N/A
The structural parts of the motor or of the
appliance provide the equivalent of such a barrie
N/A
The protection provided with the motor is such that
no burning insulation or molten material falls to the
surface that supports the appliance when the
motor is energized under each of the following
fault conditions
N/A